Inspection Detail
Inspection: 316612563 - Guardian Industries Corp.
Inspection Information - Office: Iowa 0751910
Site Address:
Guardian Industries Corp.
300 S. 5th Avenue E.
Dewitt, IA 52742
Mailing Address:
P.O. Box 180, 701 E. Lake Street, Dewitt, IA 52742
Union Status: NonUnion
SIC:3211
NAICS: 327211/Flat Glass Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/02/2012
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 07/13/2012
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 200535763 | Yes |
Investigation Summary
On June 16, 2012, Employee #1, working for Guardian Industries Corp. was assisting maintenance with changing the machine from 4 belts to 1 belt of a Tempering cooling fan. Employee #1's hand followed the belt up and became pinched between the belt and Pulley, resulting in the employee's thumb on her right hand to be amputated. The employee was not hospitalized for her injury.
Keywords: MAINTENANCE, AMPUTATED, FAN, BELT, THUMB, PULLEY, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 316612563 | Non Hospitalized injury | Amputation | Occupation not reported |