Powered by GoogleTranslate

Inspection Detail

Inspection: 316606698 - Smith Electric Co Inc

Inspection Information - Office: Va-E-Norfolk (Regional Office) - Safety 0355112

 

Inspection Nr: 316606698
Report ID: 0355112
Date Opened: 07/02/2012

Site Address:
Smith Electric Co Inc
814 Kempsville Road
Norfolk, VA 23502

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:1731

NAICS: 238210/Electrical Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/13/2012

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 03/18/2013


Related Activity
Type Activity Nr Safety Health
Accident 100924497
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1
Initial Penalty $9,100 $0 $0 $0 $0 $9,100
Current Penalty $3,500 $0 $0 $0 $0 $3,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260403 H 12/18/2012 12/21/2012 $7,000 $7,000 $0 I - Informal Settlement Citation has been deleted.
2. 01002 Serious 19260417 A 12/18/2012 12/22/2012 $2,100 $2,100 $0 I - Informal Settlement Citation has been deleted.
3. 01003A Serious 19260403 H 12/18/2012 12/21/2012 $3,500 $0 $0 Q - National Office Adjustment  
4. 01003B Serious 19260417 A 12/18/2012 12/22/2012 $0 $0 $0 Q - National Office Adjustment  

Investigation Summary

Investigation Nr: 200926350
Event: 06/27/2012
Supervisor Killed in Fall after Electrical Shock

On June 27, 2012, an employee, a supervisor for Smith Electric Co., Inc., which was a subcontractor of T.H. March Construction Co., was standing on a stepladder while installing wiring for a ceiling light fixture at a commercial building. The employee made contact with an energized wire and received an electrical shock. He fell from the ladder onto the floor, sustaining closed head injuries. The employee died, with cause of death listed as concussion.

Keywords: HEAD, STEPLADDER, ELECTRIC SHOCK, CONCUSSION, SHOCK, INSTALLING, LIGHTING FIXTURE, CONSTRUCTION, FALL, FALL PROTECTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 316606698 Fatality Concussion Supervisors; electricians & power transm. install.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.