Inspection Detail
Inspection: 316522150 - Nibbelink Masonry Construction Corporation
Inspection Information - Office: Sacramento District Office
Site Address:
Nibbelink Masonry Construction Corporation
5454 Crossings Dr
Rocklin, CA 95677
Mailing Address:
2010 West Ave K #823, Lancaster, CA 93536
Union Status: NonUnion
SIC:1741
NAICS: 238140/Masonry Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/29/2013
Emphasis:
Case Closed: 07/12/2013
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102683760 |
Investigation Summary
On April 9, 2013, Employee #1, a brick tender, was using a STIHL cut-off saw to cut rebar. The employee filled the saw with gasoline and replaced the cap. Fuel leaked from the STIHL cut-off saw and a spark ignited the leaked fuel. The employee was burned on his left arm and leg. The employee was transported to the Sutter Hospital by coworkers and was then transferred to UC Davis Burn unit, where he was treated for the burns. Employee #1 remained hospitalized for ten days.
Keywords: BURN, LEAK, REBAR, SAW, BRICK, FUEL OIL, ARM, LEG
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 316522150 | Hospitalized injury | Burn/Scald(Heat) | Construction laborers |