Powered by GoogleTranslate

Inspection Detail

Inspection: 316520733 - Bien Padre Foods Llc

Inspection Information - Office: Sacramento District Office

 

Inspection Nr: 316520733
Report ID: 0950621
Date Opened: 01/17/2013

Site Address:
Bien Padre Foods Llc
1459 Railroad Ave
Eureka, CA 95501

Mailing Address:
1459 Railroad Ave, Eureka, CA 95501

Union Status: NonUnion

SIC:2099

NAICS: 311830/Tortilla Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/01/2013

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 04/25/2017


Related Activity
Type Activity Nr Safety Health
Accident 102682580
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $15,750 $0 $0 $1,120 $0 $16,870
Current Penalty $7,000 $0 $0 $450 $0 $7,450
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3314 G02 A 02/04/2013 02/22/2013 $225 $560 $0 03/01/2013 F - Formal Settlement  
2. 01002 Other 5157 C02 02/04/2013 02/22/2013 $225 $560 $0 03/01/2013 F - Formal Settlement  
3. 02001 Serious 3314 C 02/04/2013 02/07/2013 $7,000 $15,750 $0 03/01/2013 F - Formal Settlement  

Investigation Summary

Investigation Nr: 170784573
Event: 12/11/2012
Employee Catches and Amputates Finger in Pump

On December 11, 2012, Employee #1 was using a pump to transfer cooked corn from cooking tanks to corn soaking storage tanks. He disconnected the hose that ran from the cook tank to the corn transfer pump at the pump's in-feed location. Employee #1 then used his fingers to wipe away residual from within the interior of the pump's in-take manifold. The electric motor used to drive the pump was still energized and the pump was operating. Further, there were no attempts made to deenergize or lock out the motor prior to cleaning the pump. As Employee removed the residual from within the pump, the rotating parts of the pump caught his right index finger and amputated it at the distal joint. Employee #1 was transported to a nearby medical center, where he underwent medical treatment and was then hospitalized.

Keywords: ROTATING PARTS, AMPUTATED, FINGER, CLEANING, CAUGHT BY, LOCKOUT, PUMP

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 316520733 Hospitalized injury Amputation Food batchmakers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.