Powered by GoogleTranslate

Inspection Detail

Inspection: 316515584 - The Sun Valley Group Inc

Inspection Information - Office: Sacramento District Office

 

Inspection Nr: 316515584
Report ID: 0950621
Date Opened: 04/18/2013

Site Address:
The Sun Valley Group Inc
3160 Upper Bay Rd
Arcata, CA 95521

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:0181

NAICS: 111422/Floriculture Production


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 07/03/2013

Emphasis:

Case Closed: 07/27/2015


Related Activity
Type Activity Nr Safety Health
Accident 102683869
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 5 8
Current Violations 3 5 8
Initial Penalty $31,500 $0 $0 $2,150 $0 $33,650
Current Penalty $24,750 $0 $0 $1,590 $0 $26,340
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 14300029 B03 07/12/2013 07/22/2013 $375 $375 $0 08/21/2013 F - Formal Settlement  
2. 01002 Other 3203 A 07/12/2013 07/22/2013 $560 $560 $0 08/21/2013 F - Formal Settlement  
3. 01003 Other 5144 C01 07/12/2013 08/14/2013 $280 $420 $0 08/21/2013 F - Formal Settlement  
4. 01004 Other 5162 E 07/12/2013 07/22/2013 $0 $420 $0 08/21/2013 F - Formal Settlement  
5. 01005 Other 5194 F04 07/12/2013 07/22/2013 $375 $375 $0 08/21/2013 F - Formal Settlement  
6. 02001 Serious 3329 B 07/12/2013 07/22/2013 $18,000 $18,000 $0 08/21/2013 F - Formal Settlement  
7. 03001 Serious 4310 A01 07/12/2013 07/22/2013 $3,375 $6,750 $0 08/21/2013 F - Formal Settlement  
8. 04001 Serious 5162 C 07/12/2013 07/22/2013 $3,375 $6,750 $0 08/21/2013 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202674966
Event: 04/11/2013
Employee Sustains Chemical Burns from Nitric Acid Spray

On April 11, 2013, Employee #1, with the Sun Valley Group Inc., was transferring nitric acid from a drum to an irrigation tank, when concentrated nitric acid was sprayed on him from holes in improper tubing from the drum. Employee #1 was hospitalized for two days for treatment of second degree burns on multiple body parts. The employer received a serious, accident related citation for failing to maintain the piping/tubing in accordance with good engineering practice.

Keywords: MAINTENANCE, INADEQUATE MAINT, DRUM, PRESSURE PIPING, NITRIC ACID, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 316515584 Hospitalized injury Burn(Chemical) Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close