Inspection: 316209337 - R. W. Lyall & Company Inc

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 316209337
Report ID: 0950633
Date Opened: 08/31/2012

Site Address:
R. W. Lyall & Company Inc
2665 Research Drive
Corona, CA 92882

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3823

NAICS: 334513/ Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/04/2013

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 03/28/2014


Related Activity
Type Activity Nr Safety Health
Accident 102753316
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $18,000 $0 $0 $0 $0 $18,000
Current Penalty $0 $0 $0 $7,000 $0 $7,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 4215 A 02/04/2013 02/07/2013 $7,000 $18,000 $0 02/19/2013 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202673042
Event: 08/22/2012
Employee Suffers Partial Amputattion While Operating Press

At 7:00 a.m. on August 22, 2012, Employee #1 was operating an EFV assembly hydraulically powered press. The press was being used to assemble and install Excess Flow Vale into a polyethylene pipe. Employee #1 inserted a 10 inch long by 1 inch in diameter polyethylene pipe and EFV assembly in the press, closed the front slide guard gate and turned "on" the power. Employee #1 accessed the moving pipe support plate and the housing from under the gate with her left middle finger that got pinched causing a partial amputation of her finger. Her supervisor drove her to Kaiser Hospital for treatment. Surgery was performed and she was discharged the same day. It was determined that the cause of the accident was that the hydraulic press was not guarded in a manner to prevent an employee's hand from accessing the point of operation.

Keywords: AMPUTATED, FINGER, EQUIPMENT OPERATOR, STRUCK AGAINST, PIPE, HYDRAULIC PRESS, UNGUARDED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 316209337 Non Hospitalized injury Amputation Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.