Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 316208875
Report ID: 0950633
Date Opened: 08/08/2012

Site Address:
All Intercity Plumbing
45885 Verba Santa Drive
Palm Desert, CA 92260

Mailing Address:
255 N El Cielo Road Suite #411, Palm Springs, CA 92262

Union Status: NonUnion

SIC:1711

NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 01/09/2013

Emphasis:

Case Closed: 03/28/2014


Related Activity
Type Activity Nr Safety Health
Accident 102752797
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2 4
Current Violations 1 2 3
Initial Penalty $4,720 $0 $0 $280 $0 $5,000
Current Penalty $1,575 $0 $0 $85 $0 $1,660
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 1509 E 01/11/2013 02/06/2013 $0 $85 $0 02/01/2013 F - Formal Settlement  
2. 01002 Other 3395 F03 01/11/2013 02/06/2013 $85 $195 $0 02/01/2013 F - Formal Settlement  
3. 02001 Serious 1509 A 01/11/2013 02/06/2013 $0 $2,360 $0 02/01/2013 F - Formal Settlement Citation has been deleted.
4. 03001 Serious 3395 F01 01/11/2013 02/06/2013 $1,575 $2,360 $0 02/01/2013 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202655460
Event: 07/10/2012
Worker Suffers Kidney Injury from Dehydration

At approximately 6:00 p.m. on July 10, 2012, Employee #1, a 45-year-old male plumber with All Intercity Plumbing, was installing a water heater in a laundry room of a residential home located in Palm Desert, California. Employee #1 initially began to have cramping in his hands and then in his legs while he installed the new water heater. Employee #1 was working alone while his supervisor was at another location. Employee #1 had completed two other work orders earlier that day consisting of an installation of a water heater and an installation of a garbage disposal. Both work orders were in indoor settings. The maximum ambient temperature in Palm Desert, CA was recorded at 120 degrees Fahrenheit. Employee #1 stated that he had not performed any outdoor work projects that day. Employee #1 was evaluated at an urgent care facility and then referred to Desert Regional Hospital. Employee #1 was admitted at approximately 10:53 p.m. for dehydration, acute kidney injury, rhabdomyolysis, hyperlipidemia. Employee #1 was discharged after receiving treatment on July 12, 2012. All Intercity Plumbing is primarily engaged in providing repair, new installation of plumbing and other plumbing related services at commercial establishments and residential homes. Employee #1 had been employed by All Intercity Plumbing for approximately eight months prior to the incident.

Keywords: HEAT EXHAUSTION, KIDNEY

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 316208875 Hospitalized injury Other Plumbers, pipefitters and steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.