Powered by GoogleTranslate

Inspection Detail

Inspection: 316206754 - Divizia Family Trust C/O Mary Jo Divizia Trustee

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 316206754
Report ID: 0950633
Date Opened: 03/17/2012

Site Address:
Divizia Family Trust C/O Mary Jo Divizia Trustee
8454 Autumn Leaf Dr
Rancho Cucamonga, CA 91730

Mailing Address:
1215 Anchors Way #197, Ventura, CA 93001

Union Status: NonUnion

SIC:1531

NAICS: 236118/Residential Remodelers


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/11/2012

Emphasis:

Case Closed: 12/21/2012


Related Activity
Type Activity Nr Safety Health
Accident 102751583
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $700 $0 $700
Current Penalty $0 $0 $0 $700 $0 $700
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 1509 A 09/11/2012 09/25/2012 $350 $350 $0 -  
2. 01002 Other 3662 09/11/2012 09/25/2012 $350 $350 $0 -  

Investigation Summary

Investigation Nr: 202648333
Event: 03/16/2012
Fumes from Combustion Engine Kills Three Painters

At approximately 2:54 p.m. on March 16, 2012, Employee #1, a 44-year-old male, Employee #2, 27-year-old male, and Employee #3, all painters with Divizia Family Trust C/O Mary Jo Divizia Trustee were found unresponsive by the owner of a property located in Rancho Cucamonga, California. Emergency Medical services were summoned. The Fire Department and San Bernardino Sheriff Department showed up and found an internal combustion engine driven air compressor(RIGID, 10.3 SCFM, 90 psi, 9 gallons) which had run out of fuel and the power switch of the air compressor was in ON position. All three Employees were pronounced dead at the site. Employee #1, Employee #2, and Employee #3, were hired by the owner, which was a Family Trust of the property to paint the interior of the building and some repair work.

Keywords: ENCLOSED SPACE, COMPRESSOR, ENGINE, TOXIC FUMES

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 316206754 Fatality Other Painters, construction and maintenance
2 316206754 Fatality Other Painters, construction and maintenance
3 316206754 Fatality Other Painters, construction and maintenance
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close