Inspection Detail
Inspection: 316176569 - Borghi Usa, Ltd.
Inspection Information - Office: Iowa 0751910
Site Address:
Borghi Usa, Ltd.
402 W. Division Street
West Burlington, IA 52665
Mailing Address:
P.O. Box 433, W Burlington, IA 52665
Union Status: NonUnion
SIC:3498
NAICS: 332996/Fabricated Pipe and Pipe Fitting Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/17/2011
Emphasis: L:Amputate, N:Amputate
Case Closed: 07/10/2012
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 200534949 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 2 | 5 | |||
| Current Violations | 3 | 2 | 5 | |||
| Initial Penalty | $8,400 | $0 | $0 | $1,400 | $0 | $9,800 |
| Current Penalty | $4,200 | $0 | $0 | $700 | $0 | $4,900 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100147 C01 | 01/02/2012 | 02/16/2012 | $1,750 | $3,500 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19100212 A01 | 01/02/2012 | 04/16/2012 | $1,750 | $3,500 | $0 | P - Petition to Mod Abatement | ||
| 3. | 01003 | Serious | 19100252 B02 III | 01/02/2012 | 01/26/2012 | $700 | $1,400 | $0 | I - Informal Settlement | ||
| 4. | 02001 | Other | 19040029 B01 | 01/02/2012 | 01/12/2012 | $350 | $700 | $0 | I - Informal Settlement | ||
| 5. | 02002 | Other | 19040033 B | 01/02/2012 | 01/19/2012 | $350 | $700 | $0 | I - Informal Settlement |
Investigation Summary
On October 19, 2011, Employee #1, of Borghi Usa, Ltd, had set up a machine and noticed oil on the inside of the die tooling. The machine was in the run position and the foot pedal actuator was live. Employee #1 reached in to clean the die and hit the active foot switch, which caused the clamping mechanism to cycle. As the clamp closed, his left index and middle fingers were pinched and later were amputated at the hospital.
Keywords: AMPUTATED, FINGER, CLEANING, FOOT CONTROL, LUBRICATING FLUID, LOCKOUT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 316176569 | Hospitalized injury | Amputation | Occupation not reported |
Translate