Inspection Detail
Inspection: 315943654 - Comprehensive Club Management Inc
Inspection Information - Office: Or-E-Portland - Safety 1 1054111
Site Address:
Comprehensive Club Management Inc
1111 Sw 10th Ave
Portland, OR 97205
Mailing Address:
Po Box 12606, Portland, OR 97212
Union Status: NonUnion
SIC:7997
NAICS: 713940/Fitness and Recreational Sports Centers
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 08/23/2011
Planning Guide: Health-Manufacturing
Emphasis:
Case Closed: 02/09/2012
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $495 | $0 | $0 | $0 | $0 | $495 |
| Current Penalty | $495 | $0 | $0 | $0 | $0 | $495 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19101200 H02 I | 09/15/2011 | 10/16/2011 | $165 | $165 | $0 | - | ||
| 2. | 01001B | Serious | 19101200 G08 | 09/15/2011 | 10/16/2011 | $0 | $0 | $0 | - | ||
| 3. | 01001C | Serious | 19101200 E01 | 09/15/2011 | 10/16/2011 | $0 | $0 | $0 | - | ||
| 4. | 01002A | Serious | 19100134 E01 | 09/15/2011 | 10/16/2011 | $165 | $165 | $0 | - | ||
| 5. | 01002B | Serious | 19100134 H02 I | 09/15/2011 | 10/16/2011 | $0 | $0 | $0 | - | ||
| 6. | 01003 | Serious | 702016105 A AI | 09/15/2011 | 10/16/2011 | $165 | $165 | $0 | - |
Investigation Summary
At approximately 9:15 p.m. on August 15, 2011, Employee #1 was refilling the chemical tanks in the basement mechanical room. The pool has a self feeding acid distribution system that regulates the PH level. The chemical distributor mistakenly delivered sodium hypochlorite instead of muriatic acid. The two chemicals were in the same sized containers and in similar packaging. The liquid sodium hypochlorite was added to the pool's muriatic acid feed tank in the basement mechanical room. There was about six gallons of acid remaining in the tank and one gallon of sodium hypochlorite was added. The two chemicals reacted forming chlorine gas. Employee #1 noticed a noxious odor and evacuated the basement quickly. Employee #1's exposure was short and his symptoms were limited to dizziness. Employee #1 was wearing goggles a half faced respirator with HEPA filters.
Keywords: POOL, DIZZINESS, TANK, CHEMICAL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 315943654 | Non Hospitalized injury | Asphyxia | Occupation not reported |
Translate