Inspection Detail
Inspection: 315941146 - Rogue Valley Microdevices Inc
Inspection Information - Office: Medford
Site Address:
Rogue Valley Microdevices Inc
943 Automation Way Ste F
Medford, OR 97504
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3674
NAICS: 334413/Semiconductor and Related Device Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/05/2012
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 04/25/2013
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $2,360 | $0 | $0 | $0 | $0 | $2,360 |
| Current Penalty | $2,360 | $0 | $0 | $0 | $0 | $2,360 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100333 A01 | 12/21/2012 | 12/26/2012 | $1,400 | $1,400 | $0 | - | ||
| 2. | 01002 | Serious | 702013405 A | 12/21/2012 | 12/26/2012 | $840 | $840 | $0 | - | ||
| 3. | 01003 | Serious | 702002608 A A | 12/21/2012 | 12/26/2012 | $120 | $120 | $0 | - |
Investigation Summary
On October 11, 2012, Employee #1 was performing maintenance on a HEPA fan unit. The unit was not deenergize or lockout and tagged out. He made contact with its energized conductors and burned his hands. Employee #1 was transported to a medical center, where he underwent burn treatment and was then hospitalized.
Keywords: BURN, MAINTENANCE, STRUCK AGAINST, LOCKOUT, ELEC CIRC PART--MISC, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 315941146 | Hospitalized injury | Electric Shock | Electricians |
Translate