Powered by GoogleTranslate

Inspection Detail

Inspection: 315917773 - Stevens Electric & Pump Service, Inc.

Inspection Information - Office: Augusta Area Office

 

Inspection Nr: 315917773
Report ID: 0111100
Date Opened: 09/27/2011

Site Address:
Stevens Electric & Pump Service, Inc.
Turbats Creek
Kennebunkport, ME 04046

Mailing Address:
P.O. Box 238, Monmouth, ME 04259

Union Status: NonUnion

SIC:7699

NAICS: 562991/Septic Tank and Related Services


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/17/2011

Emphasis: S:Electrical

Case Closed: 05/03/2012


Related Activity
Type Activity Nr Safety Health
Accident 102237724
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $16,800 $0 $0 $0 $0 $16,800
Current Penalty $16,800 $0 $0 $0 $0 $16,800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100146 D03 III 10/18/2011 10/22/2011 $4,200 $4,200 $0 I - Informal Settlement  
2. 01002 Serious 19100146 D04 II 10/18/2011 10/22/2011 $4,200 $4,200 $0 I - Informal Settlement  
3. 01003A Serious 19100146 D05 I 10/18/2011 10/22/2011 $4,200 $4,200 $0 I - Informal Settlement  
4. 01003B Serious 19100146 D05 II 10/18/2011 10/22/2011 $0 $0 $0 I - Informal Settlement  
5. 01004 Serious 19100146 K03 I 10/18/2011 10/22/2011 $4,200 $4,200 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 202220836
Event: 09/21/2011
Two Employees Die from H2s Exposure in a Confined Space

On September 21, 2011 Employee #1 and Employee #2 of Stevens Electric & Pump Service, Inc. , were found dead inside a sewer tank, a confined space. They died from exposure to hydrogen sulfide. The space had been improperly isolated, no air monitoring had been performed, no air supplied to the space and no retrieval system used by the person entering into the confine space.

Keywords: SEWER, CONFINED SPACE, HYDROGEN SULFIDE, AIR MONITORING, TANK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 315917773 Fatality Other Occupation not reported
2 315917773 Fatality Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close