Inspection Detail
Inspection: 315896571 - Good Gutter Inc
Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health
Site Address:
Good Gutter Inc
508 Main Street
Mardela Springs, MD 21837
Mailing Address:
P.O. Box 24, 24825 Ocean Gateway, Mardela Springs, MD 21837
Union Status: NonUnion
SIC:1761
NAICS: 238390/Other Building Finishing Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/30/2011
Planning Guide: Safety-Construction
Emphasis: L:Electric, S:Construction (1500-1799)
Case Closed: 12/09/2011
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102596103 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $3,800 | $0 | $0 | $0 | $0 | $3,800 |
| Current Penalty | $2,555 | $0 | $0 | $0 | $0 | $2,555 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19261053 B12 | 10/11/2011 | 10/19/2011 | $2,233 | $2,900 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19261060 A01 V | 10/11/2011 | 11/28/2011 | $322 | $900 | $0 | I - Informal Settlement |
Investigation Summary
On September 9, 2011, Employee #1 was working for a roofing company. Employee #1 was standing on a 40-foot aluminum extension ladder and had replaced approximately 10 feet of white aluminum fascia on the rake edge of a church roof. Employee #1 descended the ladder and attempted to lower the extension ladder. The ladder came within close proximity of an overhead 7200-volt power line located approximately 32 feet above ground and within approximately 10 to 13 feet of the eaves of the church building. The ladder became energized and Employee #1 was electrocuted.
Keywords: EXTENSION LADDER, OVERHEAD POWER LINE, ELECTROCUTED, LADDER, ROOFER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 315896571 | Fatality | Electric Shock | Construction laborers |