Powered by GoogleTranslate

Inspection Detail

Inspection: 315879916 - Rhodes Pump Sales & Service Co

Inspection Information - Office: Utah Division Of Occupational Safety And Health

 

Inspection Nr: 315879916
Report ID: 0854910
Date Opened: 08/20/2012

Site Address:
Rhodes Pump Sales & Service Co
422 S 3430 E
New Harmony, UT 84757

Mailing Address:
715 N Airport Rd, Cedar City, UT 84721

Union Status: NonUnion

SIC:5084

NAICS: 423830/Industrial Machinery and Equipment Merchant Wholesalers


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/20/2012

Emphasis:

Case Closed: 06/03/2015


Related Activity
Type Activity Nr Safety Health
Accident 101569481
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations
Initial Penalty $3,000 $0 $0 $0 $0 $3,000
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100333 C03 IIIA 09/25/2012 10/28/2012 $1,500 $1,500 $0 D - Govt Dismissed Citation has been deleted.
2. 01002 Serious 19100333 C03 IIIA 09/25/2012 10/28/2012 $1,500 $1,500 $0 D - Govt Dismissed Citation has been deleted.

Investigation Summary

Investigation Nr: 201562816
Event: 08/16/2012
Employee Is Electrocuted When in Contact with Power Line

On August 16, 2012, Employee #1 was working on a water well pump. Two coworkers were removing bolts from the water pump while Employee #1 was raising the boom to put into position. The employees did not notice the overhead power lines. The boom got close to the power line and an arching effect occurred energizing the truck. The popping sound startled the employees causing them to run in different directions. One coworker ran to the East into an open area. Another coworker ran to the South into an open area Employee #1 ran to the West, where the truck was parked. When the employee came in contact with the truck he received a severe electrical shock. Employee #1 suffered electrocution and was pronounced dead at the scene.

Keywords: ELECTRIC ARC, DERRICK TRUCK, ELECTRIC CABLE, ELECTROCUTED, WELL, BOLT, DRILL RIG--NON-OIL, POWDER, PUMP, WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 315879916 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close