Inspection Detail
Inspection: 315775585 - Bay Associates Wire Technologies Corporation
Inspection Information - Office: Foster City District Office
Site Address:
Bay Associates Wire Technologies Corporation
150 Jefferson Drive
Menlo Park, CA 94025
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3357
NAICS: 331491/ Nonferrous Metal (except Copper and Aluminum) Rolling, Drawing, and Extruding
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/24/2013
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 11/02/2013
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102793486 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | 6 | |||
| Current Violations | 3 | 3 | 6 | |||
| Initial Penalty | $24,300 | $0 | $0 | $5,270 | $0 | $29,570 |
| Current Penalty | $9,920 | $0 | $0 | $5,135 | $0 | $15,055 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3314 G | 07/24/2013 | 09/25/2013 | $0 | $135 | $0 | 08/14/2013 | F - Formal Settlement | |
| 2. | 01002 | Other | 3203 A | 07/24/2013 | 08/26/2013 | $135 | $135 | $0 | 08/14/2013 | F - Formal Settlement | |
| 3. | 01003 | Other | 342 A | 07/24/2013 | 08/26/2013 | $5,000 | $5,000 | $0 | 08/14/2013 | F - Formal Settlement | |
| 4. | 02001 | Serious | 3314 C | 07/24/2013 | 08/26/2013 | $7,200 | $14,400 | $0 | 08/14/2013 | F - Formal Settlement | |
| 5. | 03001 | Serious | 4184 B | 07/24/2013 | 08/26/2013 | $2,475 | $4,950 | $0 | 08/14/2013 | F - Formal Settlement | |
| 6. | 04001 | Serious | 3328 B | 07/24/2013 | 08/26/2013 | $245 | $4,950 | $0 | 08/14/2013 | F - Formal Settlement |
Investigation Summary
At approximately 11:30 a.m. on March 19, 2013, Employee #1 was cutting heat shrink tubing on an automatic cutting machine (Schleuniger OmniCut 3950). The cutting machine consisted of a control panel, pressure control knob, pressure gage, emergency switch, wire guides and wire exit point. The equipment was a combination electric/pneumatic trimming device for cutting wire cables and tubing of all kinds to any length. The machine was programmed using a control panel. Once programmed, the machine automatically processed the material at the designed quantity and length. The cut wire or tubing was then ejected out of the machine's exiting point at high speed. The unguarded exit point opening of the machine was measured at 4 in. by 3 in. with a distance from the opening to the point of the cutting blade operation was approximately 5 in. The Operating Instructions for the Schleuniger OmniCut 3950 showed that the exit point was provided with a built-in protection/safety barrier; however, it was not in place when Employee #1 was using the machine. As he operated the machine, Employee #1 noticed that the heat shrink tubing had folded over or coiled. He decided to use his right hand and reach up through the unguarded exit point of the machine to straighten out the heat shrink tubing near the moving cutting blade. When he did this, his hand contacted the moving blades, which amputated his index and middle fingertips. Emergency medical personnel were summoned. They arrived and transported Employee #1 to a medical center, where he underwent treatment and was then released on the same day.
Keywords: AMPUTATED, FINGER, CAUGHT BY, BLADE, UNGUARDED, MACHINE--MISC
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 315775585 | Non Hospitalized injury | Amputation | Technicians, n.e.c. |