Powered by GoogleTranslate

Inspection Detail

Inspection: 315773622 - Van Ngo Dba Euro Nail Spa

Inspection Information - Office: Foster City District Office

 

Inspection Nr: 315773622
Report ID: 0950613
Date Opened: 12/16/2011

Site Address:
Van Ngo Dba Euro Nail Spa
1155 California Dr., Ste F
Burlingame, CA 94011

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7231

NAICS: 812113/Nail Salons


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/30/2012

Emphasis:

Case Closed: 08/31/2013


Related Activity
Type Activity Nr Safety Health
Accident 101138873
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 1 3 4
Initial Penalty $10,800 $0 $0 $5,750 $0 $16,550
Current Penalty $4,050 $0 $0 $5,750 $0 $9,800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 05/31/2012 07/03/2012 $375 $375 $0 06/21/2012 W - Empr Withdrew  
2. 01002 Other 5194 E01 05/31/2012 07/03/2012 $375 $375 $0 06/21/2012 W - Empr Withdrew  
3. 01003 Other 342 A 05/31/2012 07/03/2012 $5,000 $5,000 $0 06/21/2012 W - Empr Withdrew  
4. 02001 Serious 5543 C 05/31/2012 06/13/2012 $4,050 $10,800 $0 06/21/2012 J - ALJ Decision  

Investigation Summary

Investigation Nr: 201128923
Event: 12/03/2011
Polish Remover Vapor Ignites, Burns Employee

On December 3, 2011, Employee #1, of Van Ngo Dba Euro Nail Spa, was performing her duties in the salon. Tea candles were lit and placed near a jar of nail polish remover. It was believed that vapors from the nail polish remover were ignited by the burning tea candles. Employee #1 was close to the jar and her clothing caught on fire. As a result, she suffered second degree burns to her body. She was transported to the hospital and treated for her injuries.

Keywords: BURN, CLOTHING, NAIL, VAPOR, FIRE, TOXIC FUMES

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 315773622 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close