Powered by GoogleTranslate

Inspection Detail

Inspection: 315677781 - Paiute Pipeline Company

Inspection Information - Office: Nv-E-Reno 0953210

 

Inspection Nr: 315677781
Report ID: 0953210
Date Opened: 08/18/2011

Site Address:
Paiute Pipeline Company
Rye Patch Ml142.35
Lovelock, NV 89419

Mailing Address:
400 Eagle Station, Carson City, NV 89702

Union Status: NonUnion

SIC:4922

NAICS: 486210/Pipeline Transportation of Natural Gas


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/09/2011

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/07/2011


Related Activity
Type Activity Nr Safety Health
Accident 102270386
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $3,612 $0 $0 $0 $0 $3,612
Current Penalty $2,528 $0 $0 $0 $0 $2,528
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100212 A05 09/26/2011 09/30/2011 $2,528 $3,612 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 202252268
Event: 05/24/2011
Employee Is Struck by Rotating Part and Receives Injuries

At approximately 8:30 a.m. on May 24, 2011, Employee #1 was adjusting the governor-to-carburetor control rod on a Lincoln gasoline powered portable arc welder (Model Identification Number SA-200-F163) using a pair of pliers. While the machine's engine was running, his hand slipped and went into the path of the rotating radiator-cooling fan. The fan shroud and metal guard were removed during a previous modification of the machine, but never replaced. Employee #1 suffered a partial amputation of his ring finger, severe lacerations and fractures of his middle finger, lacerations and fractures to his index finger, and a fracture at the end of his thumb on his right hand. Employee #1 was transported to a medical center, where he underwent surgery to repair his hand. After the surgery, he was hospitalized for postoperative care.

Keywords: FRACTURE, ROTATING PARTS, AMPUTATED, FAN, FINGER, ENGINE, LACERATION, STRUCK BY, UNGUARDED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 315677781 Hospitalized injury Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.