Powered by GoogleTranslate

Inspection Detail

Inspection: 315625079 - Ringo Drilling I, L.P.

Inspection Information - Office: San Antonio Area Office

 

Inspection Nr: 315625079
Report ID: 0625500
Date Opened: 06/02/2011

Site Address:
Ringo Drilling I, L.P.
Texas Rt 163 & Rt 190 Rig #17
Ozona, TX 79563

Mailing Address:
104 Spinks Road, Tye, TX 79563

Union Status: NonUnion

SIC:1381

NAICS: 213111/Drilling Oil and Gas Wells


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/03/2011

Emphasis: L:Oilgas, S:Electrical

Case Closed: 04/04/2012


Related Activity
Type Activity Nr Safety Health
Accident 100606110
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 3 7
Current Violations 4 3 7
Initial Penalty $20,200 $0 $110,000 $0 $0 $130,200
Current Penalty $9,370 $0 $68,750 $0 $0 $78,120
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 11/17/2011 12/13/2011 $1,290 $4,400 $0 I - Informal Settlement  
2. 01002 Serious 19100022 C 11/17/2011 12/13/2011 $1,290 $4,400 $0 I - Informal Settlement  
3. 01003 Serious 19100305 B02 I 11/17/2011 12/07/2011 $1,290 $4,400 $0 I - Informal Settlement  
4. 01004 Serious 19100333 A 11/17/2011 12/13/2011 $5,500 $7,000 $0 I - Informal Settlement  
5. 02001 Repeat 19100023 C01 11/17/2011 12/13/2011 $20,625 $27,500 $0 I - Informal Settlement  
6. 02002 Repeat 19100305 G02 III 11/17/2011 12/13/2011 $27,500 $55,000 $0 I - Informal Settlement  
7. 02003 Repeat 19100334 A02 I 11/17/2011 12/13/2011 $20,625 $27,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200604775
Event: 06/01/2011
Electric Shock - Direct Contact with Energized Parts

On June 1, 2011, an employee of Ringo Drilling, LLP, was fixing a leak on a centrifugal pump below the mudhouse on drilling rig number 17. After fixing the leak, the employee opened an electrical panel box that controlled the centrifugal pump. He came into contact with circuit parts energized at 480 volts, and he was electrocuted.

Keywords: MAINTENANCE, E GI IV, ELECTRICAL, ELECTROCUTED, OIL WELL DRILLING, LOCKOUT, ELEC CIRC PART--MISC, ELECTRICAL CABINET, PUMP, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 315625079 Fatality Electric Shock Drillers, oil well
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.