Powered by GoogleTranslate

Inspection Detail

Inspection: 315533943 - Pch Garage

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 315533943
Report ID: 0950631
Date Opened: 05/10/2013

Site Address:
Pch Garage
16747 Pacific Coast Hwy
Huntington Beach, CA 90742

Mailing Address:
16747 Pacific Coast Hwy, Sunset Beach, CA 90742

Union Status: NonUnion

SIC:7539

NAICS: 811118/Other Automotive Mechanical and Electrical Repair and Maintenance


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/18/2013

Emphasis:

Case Closed: 05/03/2014


Related Activity
Type Activity Nr Safety Health
Accident 102848652
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 3 3
Initial Penalty $10,800 $0 $0 $5,350 $0 $16,150
Current Penalty $0 $0 $0 $150 $0 $150
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 06/19/2013 07/22/2013 $0 $5,000 $0 07/16/2013 F - Formal Settlement  
2. 01002 Other 3203 A 06/19/2013 07/22/2013 $0 $175 $0 07/16/2013 F - Formal Settlement Citation has been deleted.
3. 01003 Other 25000008 A01 06/19/2013 07/22/2013 $50 $175 $0 07/16/2013 F - Formal Settlement  
4. 02001 Other 5416 C 06/19/2013 06/29/2013 $100 $10,800 $0 07/16/2013 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202556080
Event: 05/01/2013
Gasoline Soaked Rag Ignites, Burns Auto Mechanic

At approximately 3:18 p.m. on May 1, 2013, Employee #1, a 32-year-old male auto mechanic with Pch Garage an automobile repair shop in Sunset Beach, California was trouble shooting the fuel injection system of a 1987 BMW sedan when a piece of gasoline soaked rag he had in his possession ignited. Employee #1 was determined to have checked the alternator with a pressure regulator when he asked a coworker to turn on the ignition trigging the fire. The gasoline vapor was suspected to have exceeded the lower explosive limit at the time when the ignition was turned on resulting in a fire. Employee #1 was taken to UCI Burn Center where he was admitted for treatment of unspecified burn injuries.

Keywords: BURN, VAPOR, AUTOMOTIVE REPAIR, FIRE, MECHANIC, GAS, AUTOMOBILE, SPARK, GASOLINE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 315533943 Hospitalized injury Burn/Scald(Heat) Helpers, mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.