Powered by GoogleTranslate

Inspection Detail

Inspection: 315530956 - Mark Gamboa Construction

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 315530956
Report ID: 0950631
Date Opened: 10/03/2012

Site Address:
Mark Gamboa Construction
3347 W. Fair Crest Dr.
Anaheim, CA 92804

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:1731

NAICS: 238210/Electrical Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/12/2012

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 07/26/2013


Related Activity
Type Activity Nr Safety Health
Accident 102815636
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $350 $0 $350
Current Penalty $0 $0 $0 $350 $0 $350
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3319 E 12/14/2012 01/16/2013 $350 $350 $0 -  

Investigation Summary

Investigation Nr: 202555181
Event: 09/29/2012
Worker Is Burned in Flashback When Gasoline Vapor Ignites

At 2:00 p.m. on September 29, 2012, Employee #1 was working in the back yard of his employer's residence in Anaheim, CA. He was performing service/maintenance to a portable electric generator in preparation for its use during the following week's work. He attempted to pull the start cord of the generator, which created a spark that ignited the gasoline vapor. In the ensuing flash fire and flashback, Employee #1 was engulfed in flame. He was hospitalized and treated for burns to his face and upper extremity. The employer reported the incident to Cal/OSHA on October 01, 2012. Cal/OSHA initiated its investigation at 11:00 a.m. on October 3, 2012. Employee #1 had been employed as a painter by the employer for approximately three months, assigned to work at various job sites. He was not a contracted employee.

Keywords: BURN, MAINTENANCE, VAPOR, FIRE, CONSTRUCTION, TORSO, FLASHBACK, SPARK, FACE, ELECTRIC GENERATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 315530956 Hospitalized injury Burn/Scald(Heat) Painters, sculptors, craft-artists & printmakers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.