Inspection: 315530113 - Pax Industries

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 315530113
Report ID: 0950631
Date Opened: 07/20/2012

Site Address:
Pax Industries
1561 Mcarthur Blvd.
Costa Mesa, CA 92626

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3086

NAICS: 326140/Polystyrene Foam Product Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/27/2012

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 01/18/2013


Related Activity
Type Activity Nr Safety Health
Accident 102777208
Complaint 208496505 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $3,710 $0 $0 $0 $0 $3,710
Current Penalty $3,710 $0 $0 $0 $0 $3,710
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 4070 A 11/28/2012 12/12/2012 $3,710 $3,710 $0 -  

Investigation Summary

Investigation Nr: 202555074
Event: 06/12/2012
Employee Crushes Finger in Pinch Point and Is Amputated

On June 12, 2012, Employee #1 was operating a roller machine, which applied glue on one side of a gasket material that is mounted on a large roll. Employee #1 had a coworker, who was assisting her with the machine. After they finished one roll of gasket material, Employee #1 mounted a new roll on the machine, but the roll would not advance. She pulled on the timing belt in the rear of the machine to get the new roll to advance. However, when the belt advanced, her left ring fingertip was crushed in the pinch point between the belt and the pulley. Employee #1 was initially taken to the U.S. Healthworks for treatment, but was then transferred to a hospital to meet with a surgical specialist. At the hospital, a surgeon repaired the damaged fingertip, which involved its amputation. She was released from the hospital following the surgical procedure.

Keywords: ROTATING PARTS, AMPUTATED, BELT, FINGER, EQUIPMENT OPERATOR, CAUGHT BY, CRUSHED, NIP POINT, PULLEY, MACHINE--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 315530113 Non Hospitalized injury Amputation Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.