Inspection Detail
Inspection: 315528745 - Aluminum Precision Products
Inspection Information - Office: Santa Ana District Office
Site Address:
Aluminum Precision Products
3132 Central Ave
Santa Ana, CA 92704
Mailing Address:
3333 W Warner Ave, Santa Ana, CA 92704
Union Status: NonUnion
SIC:3463
NAICS: 332112/Nonferrous Forging
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/26/2012
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 11/20/2012
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102777364 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $375 | $0 | $375 |
| Current Penalty | $0 | $0 | $0 | $375 | $0 | $375 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 A04 | 10/04/2012 | 10/09/2012 | $375 | $375 | $0 | - |
Investigation Summary
On November 15, 2011, Employee #1 was working as a laborer for a firm that forged aluminum products. Employee #1 was not a contract employee. The site supervisor was not on site when the incident occurred. Employee #1 was using a cigarette lighter to look through a vent pipe into a portable wastewater transfer tank. The tank contained unidentified waste and flammable vapors. They were ignited by the lighter. The employee sustained serious flash burn injuries to his eyes, face, and hand. The incident was reported to the Division on the same day.
Keywords: BURN, EYE, VAPOR, FLAMMABLE VAPORS, METAL SHOP, FACE, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 315528745 | Hospitalized injury | Burn/Scald(Heat) | Laborers, except construction |