Powered by GoogleTranslate

Inspection Detail

Inspection: 315458828 - Superior Ready Mix Concrete Lp

Inspection Information - Office: Van Nuys Mining & Tunneling District Office

 

Inspection Nr: 315458828
Report ID: 0950652
Date Opened: 10/21/2011

Site Address:
Superior Ready Mix Concrete Lp
7500 Mission Gorge Rd
San Diego, CA 92120

Mailing Address:
1508 West Mission Rd, Escondido, CA 92029

Union Status: NonUnion

SIC:2951

NAICS: 324121/Asphalt Paving Mixture and Block Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/02/2011

Emphasis: L:Tunnel

Case Closed: 01/08/2013


Related Activity
Type Activity Nr Safety Health
Accident 362177180
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 2 2
Initial Penalty $5,060 $0 $0 $280 $0 $5,340
Current Penalty $0 $0 $0 $840 $0 $840
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5194 H01 02/01/2012 02/06/2012 $280 $280 $0 -  
2. 02001 Other 5162 A 02/01/2012 02/06/2012 $560 $5,060 $0 02/22/2012 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202422333
Event: 10/12/2011
Employee Suffers Burns from Hot Asphalt

At approximately 4:30 a.m. on October 12, 2011, Employee #1, a truck driver, delivered a load of hot paving asphalt at a temperature of approximately 325 degrees Fahrenheit, twice per day. It was pumped out of a tanker trailer into storage tanks. The truck used to bring the hot asphalt to the plant was a Peterbilt Model Number 379, and License Plate Number 9E62537 (Employer Equipment Number 8139), pulling an insulated 7,000-gal tanker trailer (Employer Equipment Number 9111). The tank was equipped with an internal ball valve that sat at the bottom of the tank and was opened and shut from the top of the trailer. Below the ball valve, underneath the trailer, was a 4-inch diameter vertical pipe that teed off to both sides of the trailer. Each side had a gate valve operated by a wheel. After the gate valve, the outlet pipes narrowed to 3 inches. On the end of each outlet pipe was a metal cap held in place by two cam latches. With the cap off and both valves open, the asphalt could be pumped through a hose into holding tanks. On the previous morning, Employee #1 forgot to close the bottom gate valve. When he returned with a load of asphalt, he put on his PPE, which included coveralls, 12-inch rubber gloves, safety glasses, and a hard hat with a wire screen face shield. He went on top of the truck first and opened the internal ball valve. He came down and without checking the lower gate valve, which he had left open the day before, he took off the cap on the outlet pipe. He was sprayed on his left arm and chest with the hot asphalt. It splashed up underneath his face shield, and ran down into both gloves. He was taken to a nearby hospital, evaluated, and sent via ambulance to UCSD Burn Center. He suffered serious burns to both wrists and a third of his face. He was admitted, had skin grafts on both wrists on October 17, 2011, and was released from the hospital on October 22, 2011.

Keywords: BURN, CHEST, TANK TRUCK, PPE, GLOVE, VALVE, ARM, ASPHALT, TRUCK DRIVER, WRIST

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 315458828 Hospitalized injury Burn/Scald(Heat) Truck drivers, heavy
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close