Inspection Detail
Inspection: 315428599 - Great Northwest Gutters Llc
Inspection Information - Office: Or-E-Portland - Safety 1 1054111
Site Address:
Great Northwest Gutters Llc
2480 Nw Quimby St
Portland, OR 97210
Mailing Address:
19975 Sw Cipole Rd, Sherwood, OR 97140
Union Status: NonUnion
SIC:1761
NAICS: 238170/Siding Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/10/2011
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 01/31/2012
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $5,000 | $0 | $0 | $0 | $0 | $5,000 |
| Current Penalty | $2,500 | $0 | $0 | $0 | $0 | $2,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 703004702 | 10/21/2011 | 10/26/2011 | $2,500 | $5,000 | $0 | 11/04/2011 | L - State Settlement |
Investigation Summary
On July 19, 2011, Employees #1 and #2 were working on a residential construction project at a multifamily residence. Employees #1 and #2 were standing on aluminum extension ladders and were installing a 53 foot length of gutter on the roof. The gutter contacted a high voltage power line. Employees #1 and #2 were shocked, and they slipped from the ladders and fell approximately 18 feet to the ground below.
Keywords: SHOCK, INSTALLING, ROOF, LADDER, FALL, FALL PROTECTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 315428599 | Hospitalized injury | Electric Shock | Occupation not reported | ||
| 2 | 315428599 | Hospitalized injury | Electric Shock | Occupation not reported |
Translate