Powered by GoogleTranslate

Inspection Detail

Inspection: 315071126 - Marquez Brothers International, Inc.

Inspection Information - Office: Fresno District Office

 

Inspection Nr: 315071126
Report ID: 0950625
Date Opened: 08/17/2011

Site Address:
Marquez Brothers International, Inc.
179 S 11th Avenue
Hanford, CA 93230

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2022

NAICS: 311513/Cheese Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/11/2012

Emphasis:

Case Closed: 04/23/2013


Related Activity
Type Activity Nr Safety Health
Accident 101084598
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 3 5
Current Violations 1 3 4
Initial Penalty $26,435 $0 $0 $2,805 $0 $29,240
Current Penalty $8,435 $0 $0 $2,805 $0 $11,240
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 01/12/2012 02/14/2012 $935 $935 $0 01/27/2012 F - Formal Settlement  
2. 01002 Other 3314 C01 01/12/2012 02/14/2012 $935 $935 $0 01/27/2012 F - Formal Settlement  
3. 01003 Other 3314 G01 01/12/2012 02/14/2012 $935 $935 $0 01/27/2012 F - Formal Settlement  
4. 02001 Serious 3314 J01 01/12/2012 02/14/2012 $0 $18,000 $0 01/27/2012 F - Formal Settlement Citation has been deleted.
5. 03001 Serious 4070 A 01/12/2012 02/14/2012 $8,435 $8,435 $0 01/27/2012 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201495892
Event: 07/12/2011
Employee Fingers Are Amputated When Caught in Pulley

On July 12, 2011, Employee #1, a sanitation worker of Marquez Brothers International, Incorporated, was cleaning a CRYOVAC Rotary Vacuum Chamber machine located in CP-1 at the Hanford, CA facility. The sanitation process required the machine to be in operation. Employee #1 was authorized to access and clean the enclosure housing and the belt and pulley drive/s for the feed conveyor/s. For some unknown reason, Employee #1's left hand came into contact with the belt and pulled though the belt and pulley drive. Employee #1 was transported to the hospital and treated for the amputation of his pointer and middle fingers. Employee #1 was experienced working in CP-2, but was reassigned to CP-1, thirty days prior to this incident. It was found that the equipment and machines in CP-2 were equipped with direct drives motors, while the CRYOVAC CP-1 was equipped with belt and pulley drives and was the only machine identified in the facility required to be in operation during the sanitation process. Upon reassignment, Employee #1 was not retrained, nor was documentation provided for hazards associated with belt and pulley drive systems. The employer did not establish specific procedures and training in accordance with 8CCR Section 3314. The belt and pulley drive was determined not be effectively guarded as required by 8CCR 4070(a) based on the enclosure's door not being secured as required by 8CCR Section 3942.

Keywords: ROTATING PARTS, AMPUTATED, BELT, UNSECURED, FINGER, GUARD, WORK RULES, CLEANING, LOCKOUT, PULLEY

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 315071126 Hospitalized injury Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close