Powered by GoogleTranslate

Inspection Detail

Inspection: 314993866 - Larry Love & Michael (Mike) Withrow

Inspection Information - Office: Modesto District Office

 

Inspection Nr: 314993866
Report ID: 0950624
Date Opened: 09/21/2011

Site Address:
Larry Love & Michael (Mike) Withrow
774 Columbia Ave
Merced, CA 95340

Mailing Address:
2863 Oleander Avenue, Merced, CA 95340

Union Status: NonUnion

SIC:1761

NAICS: 238160/Roofing Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 03/19/2012

Emphasis: S:Construction (Cship)

Case Closed: 10/06/2022


Related Activity
Type Activity Nr Safety Health
Accident 102724119
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 7 7
Current Violations 7 7
Initial Penalty $31,500 $0 $0 $0 $0 $31,500
Current Penalty $31,500 $0 $0 $0 $0 $31,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 3203 A 03/19/2012 04/06/2012 $4,500 $4,500 $0 -  
2. 02001 Serious 3203 A07 03/19/2012 04/06/2012 $4,500 $4,500 $0 -  
3. 03001 Serious 1509 B 03/19/2012 04/06/2012 $4,500 $4,500 $0 -  
4. 04001 Serious 1670 A 03/19/2012 04/06/2012 $4,500 $4,500 $0 -  
5. 05001 Serious 3395 C 03/19/2012 04/06/2012 $4,500 $4,500 $0 -  
6. 06001 Serious 3395 F01 03/19/2012 04/06/2012 $4,500 $4,500 $0 -  
7. 07001 Serious 3395 F03 03/19/2012 04/06/2012 $4,500 $4,500 $0 -  

Investigation Summary

Investigation Nr: 202522140
Event: 09/19/2011
Roofer Suffers Heat-Related Seizure

At approximately 2:43 p.m. on September 19, 2011, an employee who was reroofing a single-story residential building suffered a heat-induced seizure. A call was placed requesting medical assistance. An ambulance arrived and transported the employee to Mercy Hospital in Merced, CA. The employee was admitted for inpatient care and treatment of his heat-related seizures.

Keywords: ROOFER, HEAT EXHAUSTION, HEAT, ROOF, CONSTRUCTION, HEAT STROKE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 314993866 Hospitalized injury Heat Exhaustion Roofers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close