Inspection Detail
Inspection: 314962283 - Lennox Industries Inc.
Inspection Information - Office: Iowa 0751910
Site Address:
Lennox Industries Inc.
200 S. 12th Avenue
Marshalltown, IA 50158
Mailing Address:
P.O. Box 250, Marshalltown, IA 50158
Union Status: Union
SIC:3585
NAICS: 333415/Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/24/2010
Planning Guide: Safety-Manufacturing
Emphasis: L:Amputate, N:Amputate, S:Amputate
Case Closed: 03/31/2011
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 200533198 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 4 | 4 | ||||
Current Violations | 4 | 4 | ||||
Initial Penalty | $16,700 | $0 | $0 | $0 | $0 | $16,700 |
Current Penalty | $15,800 | $0 | $0 | $0 | $0 | $15,800 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19100147 C04 I | 10/22/2010 | 04/15/2011 | $5,000 | $5,000 | $0 | 11/17/2010 | P - Petition to Mod Abatement | |
2. | 01001B | Serious | 19100147 F01 | 10/22/2010 | 04/15/2011 | $0 | $0 | $0 | 11/17/2010 | P - Petition to Mod Abatement | |
3. | 01001C | Serious | 19100217 D09 I | 10/22/2010 | 04/15/2011 | $0 | $0 | $0 | 11/17/2010 | P - Petition to Mod Abatement | |
4. | 01001D | Serious | 19100217 D09 IV | 10/22/2010 | 04/15/2011 | $0 | $0 | $0 | 11/17/2010 | P - Petition to Mod Abatement | |
5. | 01002A | Serious | 19100178 A05 | 10/22/2010 | 02/15/2011 | $4,500 | $5,000 | $0 | 11/17/2010 | W - Empr Withdrew | |
6. | 01002B | Serious | 19100178 L03 IG | 10/22/2010 | 02/15/2011 | $0 | $0 | $0 | 11/17/2010 | W - Empr Withdrew | |
7. | 01002C | Serious | 19100178 O01 | 10/22/2010 | 02/15/2011 | $0 | $0 | $0 | 11/17/2010 | W - Empr Withdrew | |
8. | 02003 | Serious | 19100212 A03 II | 10/22/2010 | 02/15/2011 | $5,000 | $5,000 | $0 | 11/17/2010 | W - Empr Withdrew | |
9. | 02004 | Serious | 19100219 B01 | 10/22/2010 | 02/15/2011 | $1,300 | $1,700 | $0 | 11/17/2010 | W - Empr Withdrew |
Investigation Summary
At approximately 11:00 a.m. on September 1, 2010, Employee #1 was using a Cincinnati Hydraulic Press brake, Model Number 90AFX8 and Serial Number 45748, to press rail fillers. The ISB-Pro Programmable Beam Blackout light curtain was working, but was not relaying actions to the press brake. A jumper had been removed from the press brake controls causing the press brake not to read the light curtains signals. Employee #1 caught his finger between the die and rail filler. He was taken to Marshalltown hospital and then transferred to Mary Greeley Hospital, where his right thumb was amputated. He was hospitalized for his injury.
Keywords: DIE, AMPUTATED, BRAKE, FINGER, MACHINE OPERATOR, LOCKOUT, CAUGHT BETWEEN, HYDRAULIC PRESS
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 314962283 | Hospitalized injury | Amputation | Pressing machine operators |