Powered by GoogleTranslate

Inspection Detail

Inspection: 314865650 - C B Collective Llc

Inspection Information - Office: Los Angeles District Office

 

Inspection Nr: 314865650
Report ID: 0950641
Date Opened: 08/22/2013

Site Address:
C B Collective Llc
1725 E. 21st St.
Los Angeles, CA 90014

Mailing Address:
5711 Carell Ave., Agoura Hills, CA 91301

Union Status: NonUnion

SIC:7812

NAICS: 512110/Motion Picture and Video Production


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/22/2013

Emphasis:

Case Closed: 11/22/2013


Related Activity
Type Activity Nr Safety Health
Accident 102765310
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $85 $0 $85
Current Penalty $0 $0 $0 $85 $0 $85
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 10/23/2013 10/28/2013 $85 $85 $0 -  

Investigation Summary

Investigation Nr: 202545349
Event: 07/28/2013
Employee Receives Burns in Flash Fire

At approximately 11:46 a.m. on July 28, 2013, Employee #1 was involved in the filming of a music video with smoke effects and participated in various scenes under the direction of a coworker. The scenes were filmed in a stage prop room approximately 9-ft by 9-ft and located in a vacant warehouse. Employee #1 was asked to run into the room illuminated by stage lighting and recorded by a videographer. On some occasions, a colored powder, Holi Powder, would be atomized around her. This activity had been performed on other occasions without incident. A close-up scene was setup with the colored powder placed into a funnel attached to a compressed air line next to and pointing at Employee #1. A high intensity and hot stage light was set between the powder funnel and her, designed to blow the colored powder onto herself. At the directed time, a coworker activated a manual valve that forced compressed air into the funnel that atomized the colored powder and blew it onto Employee #1. When the colored powder reached her, it ignited from either the hot stage light or static electricity, causing a flash fire that burned her costume, tights and hair. She also received facial burns in the incident. Stage personnel used portable fire extinguishers to put out the fire. Employee #1 received treatment at a medical center and then was released. The colored powder was determined to be 99.3 percent corn starch, which when it was atomized by the compressed air became a combustible dust that was ignited by the hot stage light or static electricity.

Keywords: BURN, HEAT, FIRE, COMPRESSED AIR, LIGHTING, COMBUSTIBLE DUST, FACE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 314865650 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.