Powered by GoogleTranslate

Inspection Detail

Inspection: 314859950 - Lausd Jefferson High

Inspection Information - Office: Los Angeles District Office

 

Inspection Nr: 314859950
Report ID: 0950641
Date Opened: 05/21/2012

Site Address:
Lausd Jefferson High
1319 E. 41st St.
Los Angeles, CA 90011

Mailing Address:
1240 Naomi Ave., Los Angeles, CA 90021

Union Status: Union

SIC:8211

NAICS: 611110/Elementary and Secondary Schools


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: LocalGovt

Safety/Health: Safety

Close Conference: 08/21/2012

Emphasis:

Case Closed: 09/07/2013


Related Activity
Type Activity Nr Safety Health
Accident 102760295
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 6
Current Violations 6 6
Initial Penalty $0 $0 $0 $3,935 $0 $3,935
Current Penalty $0 $0 $0 $3,150 $0 $3,150
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 23400016 A 08/21/2012 09/13/2012 $300 $375 $0 09/04/2012 F - Formal Settlement  
2. 01002 Other 23400022 A 08/21/2012 09/13/2012 $450 $560 $0 09/04/2012 F - Formal Settlement  
3. 01003 Other 3314 C 08/21/2012 08/24/2012 $600 $750 $0 09/04/2012 F - Formal Settlement  
4. 01004 Other 3314 G 08/21/2012 09/13/2012 $600 $750 $0 09/04/2012 F - Formal Settlement  
5. 01005 Other 3314 H 08/21/2012 09/13/2012 $600 $750 $0 09/04/2012 F - Formal Settlement  
6. 01006 Other 3320 08/21/2012 09/13/2012 $600 $750 $0 09/04/2012 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202543864
Event: 05/09/2012
Employee Amputates Fingertip in Air Compressor

At 10:00 a.m. on May 9, 2012, Employee #1, a building engineer employed by the Los Angeles United School District, was working on a Quincy Air Compressor (model number was illegible), Serial Number 200507120025, with the guard open and without deenergizing the unit. The unit started up, although no automatic start-up sign was posted, while Employee #1 was touching the belt, resulting in the amputation of his right ring finger's fingertip. Employee #1 was transported to Los Angeles County USC Medical Center, where he was treated in the Emergency Room.

Keywords: COMPRESSOR, MAINTENANCE, AMPUTATED, FINGER, LOCKOUT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 314859950 Hospitalized injury Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.