Inspection Detail
Inspection: 314857947 - Angelus Block Co Inc
Inspection Information - Office: Los Angeles District Office
Site Address:
Angelus Block Co Inc
252 E. Redondo Beach Blvd.
Gardena, CA 90248
Mailing Address:
1705 N. Main St., Orange, CA 92865
Union Status: Union
SIC:3271
NAICS: 327331/Concrete Block and Brick Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/15/2011
Emphasis:
Case Closed: 02/18/2012
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102580487 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 3 | 4 | |||
| Current Violations | 1 | 2 | 3 | |||
| Initial Penalty | $22,500 | $0 | $0 | $1,870 | $0 | $24,370 |
| Current Penalty | $18,000 | $0 | $0 | $185 | $0 | $18,185 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 A | 03/08/2011 | 03/11/2011 | $185 | $560 | $0 | 03/18/2011 | F - Formal Settlement | |
| 2. | 01002 | Other | 3314 H03 | 03/08/2011 | 03/25/2011 | $0 | $560 | $0 | 03/18/2011 | D - Govt Dismissed | Citation has been deleted. |
| 3. | 01003 | Other | 3314 G | 03/08/2011 | 03/25/2011 | $0 | $750 | $0 | 03/18/2011 | F - Formal Settlement | |
| 4. | 02001 | Serious | 3314 C | 03/08/2011 | 03/11/2011 | $18,000 | $22,500 | $0 | 03/18/2011 | F - Formal Settlement |
Investigation Summary
At 12:45 p.m. On September 10, 2010, Employee #1, with a company that manufactured concrete blocks, was clearing debris from a concrete mixer. When a coworker remotely closed the mixer's discharge door, Employee #1's hand was crushed. His middle and ring fingers were amputated. The incident was caused by failure to lock out the discharge door and failure of the coworker to check for personnel prior to activating the door.
Keywords: AMPUTATED, FINGER, CLEANING, MIXER, LOCKOUT, COMMUNICATION, DOOR, INATTENTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 314857947 | Non Hospitalized injury | Amputation | Occupation not reported |
Translate