Powered by GoogleTranslate

Inspection Detail

Inspection: 314829037 - Shadow Holdings Llc Dba Bocchi Laboratories

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 314829037
Report ID: 0950643
Date Opened: 04/11/2012

Site Address:
Shadow Holdings Llc Dba Bocchi Laboratories
26421 Ruether Ave
Santa Clarita, CA 91350

Mailing Address:
26455 Ruether Ave, Santa Clarita, CA 91350

Union Status: NonUnion

SIC:2844

NAICS: 325611/Soap and Other Detergent Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/25/2012

Emphasis:

Case Closed: 01/03/2014


Related Activity
Type Activity Nr Safety Health
Accident 102781945
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $560 $0 $560
Current Penalty $0 $0 $0 $420 $0 $420
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 06/25/2012 07/28/2012 $420 $560 $0 07/06/2012 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202471280
Event: 03/16/2012
Mechanical Valve Amputates Worker Finger While Cleaning

At approximately 8 a.m. on March 16, 2012, Employee #1, a 46-year-old male, mechanic with Shadow Holdings Llc Dba Bocchi Laboratories was performing the duties of a mechanic, including cleaning a pneumatic valve. Employee #1 had started to clean a valve manufactured by Sudmo, for not more than one minute before the incident occurred. Employee #1 asked a coworker, for his assistance to clean the valve. Employee #1 connected the valve to the Kaps-All "Filler" machine's (Serial Number: 6733) air signal in line-four where it could be actuated. Employee #1 gave the order to the coworker to actuate the valve at the control switch and commented to him that it opened. The coworker then turned the control switch to close the valve. Employee #1's fingertip was amputated as he stuck his fingers in the valve to begin cleaning it. The supervisor was not in the immediate area. Employee #1 suffered an amputation of his left ring fingertip when it was pinched by a pneumatic valve. Employee #1 was transported to Henry Mayo Hospital for treatment. The facility involved in the incident is a manufacturer of personal care products including shampoos, creams, and body lotions, and employs approximately 340 persons.

Keywords: AMPUTATED, FINGER, CLEANING, VALVE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 314829037 Hospitalized injury Amputation Helpers, mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.