Inspection Detail
Inspection: 314827759 - Shadow Holdings Llc Dba Bocchi Laboratories
Inspection Information - Office: Van Nuys District Office
Site Address:
Shadow Holdings Llc Dba Bocchi Laboratories
26421 Ruether Ave
Santa Clarita, CA 91350
Mailing Address:
26455 Ruether Ave, Santa Clarita, CA 91350
Union Status: NonUnion
SIC:2844
NAICS: 325611/Soap and Other Detergent Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/26/2012
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 11/10/2014
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102780533 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 1 | 3 | |||
Current Violations | 2 | 2 | ||||
Initial Penalty | $27,000 | $0 | $0 | $280 | $0 | $27,280 |
Current Penalty | $18,675 | $0 | $0 | $0 | $0 | $18,675 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 3203 A | 05/25/2012 | 06/27/2012 | $0 | $280 | $0 | 06/04/2012 | F - Formal Settlement | Citation has been deleted. |
2. | 02001 | Serious | 5549 B | 05/25/2012 | 06/04/2012 | $675 | $9,000 | $0 | 06/04/2012 | F - Formal Settlement | |
3. | 03001 | Serious | 5416 C | 05/25/2012 | 05/30/2012 | $18,000 | $18,000 | $0 | 06/04/2012 | F - Formal Settlement |
Investigation Summary
At approximately 8:05 p.m. on November 30, 2011, Employee #1 was cleaning and drying a stainless steel tank, using hot water and ethanol. Employee #1 also hooked up a compressed air hose at the bottom of the tank to dry the tank quicker. At the same time, Employee #2 was heating a solid product in a drum with a torch so it could be poured into a tank, approximately 15 ft from tank. The lid of the tank was opened, and ethanol vapors filled the area. An explosion and fire occurred and both Employee #1 and Employee #2 were seriously burned. Both Employee #1 and Employee #2 were hospitalized for their injuries.
Keywords: BURN, DRUM, FIRE, HOSE, TORCH, EXPLOSION, TANK
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 314827759 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
2 | 314827759 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |