Powered by GoogleTranslate

Inspection Detail

Inspection: 314827759 - Shadow Holdings Llc Dba Bocchi Laboratories

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 314827759
Report ID: 0950643
Date Opened: 01/09/2012

Site Address:
Shadow Holdings Llc Dba Bocchi Laboratories
26421 Ruether Ave
Santa Clarita, CA 91350

Mailing Address:
26455 Ruether Ave, Santa Clarita, CA 91350

Union Status: NonUnion

SIC:2844

NAICS: 325611/Soap and Other Detergent Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/26/2012

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/10/2014


Related Activity
Type Activity Nr Safety Health
Accident 102780533
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 2
Initial Penalty $27,000 $0 $0 $280 $0 $27,280
Current Penalty $18,675 $0 $0 $0 $0 $18,675
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 05/25/2012 06/27/2012 $0 $280 $0 06/04/2012 F - Formal Settlement Citation has been deleted.
2. 02001 Serious 5549 B 05/25/2012 06/04/2012 $675 $9,000 $0 06/04/2012 F - Formal Settlement  
3. 03001 Serious 5416 C 05/25/2012 05/30/2012 $18,000 $18,000 $0 06/04/2012 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202471421
Event: 11/30/2011
Two Employees Injured in Fire and Explosion

At approximately 8:05 p.m. on November 30, 2011, Employee #1 was cleaning and drying a stainless steel tank, using hot water and ethanol. Employee #1 also hooked up a compressed air hose at the bottom of the tank to dry the tank quicker. At the same time, Employee #2 was heating a solid product in a drum with a torch so it could be poured into a tank, approximately 15 ft from tank. The lid of the tank was opened, and ethanol vapors filled the area. An explosion and fire occurred and both Employee #1 and Employee #2 were seriously burned. Both Employee #1 and Employee #2 were hospitalized for their injuries.

Keywords: BURN, DRUM, FIRE, HOSE, TORCH, EXPLOSION, TANK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 314827759 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 314827759 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.