Powered by GoogleTranslate

Inspection Detail

Inspection: 314826439 - Miller Drilling Company

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 314826439
Report ID: 0950643
Date Opened: 09/01/2011

Site Address:
Miller Drilling Company
330 Penman Springs Rd.
Paso Robles, CA 93446

Mailing Address:
329 N. Main St., Templeton, CA 93465

Union Status: NonUnion

SIC:1781

NAICS: 237110/Water and Sewer Line and Related Structures Construction


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/05/2011

Emphasis:

Case Closed: 04/16/2013


Related Activity
Type Activity Nr Safety Health
Accident 102638194
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $5,375 $0 $5,375
Current Penalty $0 $0 $0 $2,875 $0 $2,875
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 10/13/2011 10/30/2011 $2,500 $5,000 $0 11/17/2011 F - Formal Settlement  
2. 01002 Other 3276 F02 10/13/2011 10/30/2011 $375 $375 $0 -  

Investigation Summary

Investigation Nr: 202470365
Event: 07/25/2011
Employee Receives Electrical Shock and Falls from Ladder

At 12:00 p.m. on July 22, 2011, a full time permanent employee, of Miller Drilling Company, Paso Robles, CA, was working on a water tank in a remote location. He climbed a metal extension ladder that had been provided by the customer and placed against the 10-foot tall metal water tank. The employee ascended the metal ladder to conduct an electrical test on a malfunctioning 110-volt tank float. He grounded himself out against the metal tank and received an electrical shock. He fell approximately 5 feet to the ground, landing on his back. He was transported to Twin Cities Hospital, Templeton, CA, and subsequently transported by ambulance to Sierra Vista Hospital, San Luis Obispo, CA. The employee was determined to have suffered a burst fracture of T9 vertebra. This accident was reported to Cal/OSHA Division on July 25, 2011, 2 days 20 hours and 55 minutes after the incident. The Division conducted an opening conference on September 1, 2011, at 9:17 a.m. Investigation determined that the employer, in the business of water well drilling, repair, and maintenance in the local area, had provided the employee a fiberglass extension ladder and rubber gloves to use when testing live circuits. The employee, however, did not use this equipment. Instead, he used the customer-provided metal extension ladder, which had no identifiable markings. The employer received a general citation under Title 8 Calif. Code of Regulations 3276(f)(2).

Keywords: FRACTURE, ELECTRICAL TESTING, GLOVE, LADDER, CONSTRUCTION, BACK, ELECTRIC SHOCK, FALL, VERTEBRA, WATER TANK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 314826439 Hospitalized injury Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close