Powered by GoogleTranslate

Inspection Detail

Inspection: 314824111 - Surface Pumps Inc.

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 314824111
Report ID: 0950643
Date Opened: 04/15/2011

Site Address:
Surface Pumps Inc.
Well #16x34 W Of Old River Rd On Copus Rd
Bakersfield, CA 93313

Mailing Address:
3301 Unicorn Rd., Bakersfield, CA 93308

Union Status: NonUnion

SIC:5084

NAICS: 423830/Industrial Machinery and Equipment Merchant Wholesalers


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/01/2011

Emphasis:

Case Closed: 08/21/2012


Related Activity
Type Activity Nr Safety Health
Accident 102636503
Accident 102636529
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 5 5
Initial Penalty $0 $0 $0 $6,375 $0 $6,375
Current Penalty $0 $0 $0 $3,375 $0 $3,375
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 09/01/2011 09/26/2011 $2,000 $5,000 $0 09/22/2011 J - ALJ Decision  
2. 01002 Other 14300032 A04 09/01/2011 09/26/2011 $275 $275 $0 09/22/2011 J - ALJ Decision  
3. 01003 Other 1512 B 09/01/2011 09/26/2011 $275 $275 $0 09/22/2011 J - ALJ Decision  
4. 01004 Other 3314 H 09/01/2011 09/26/2011 $275 $275 $0 09/22/2011 J - ALJ Decision  
5. 01005 Other 1511 B 09/01/2011 09/26/2011 $550 $550 $0 09/22/2011 J - ALJ Decision  

Investigation Summary

Investigation Nr: 202470191
Event: 03/22/2011
Employee Is Injured When Struck by Equipment

At approximately 11:00 a.m. on March 22, 2011, Employee #1, a sales representative with Surface Pumps, Inc., was assisting a field mechanic removing a positive displacement pump from its foundation at an oil well. A CoorsTek pulsation dampener (Serial Number 01011173A, Model Number 5085-3-F HNBR) was connected vertically to a pipe that ran horizontally, east to west. At the east end of the pipe, the dampener was connected to a block valve with bolts on a square flange that allowed for the pipe to swivel inside the flange. At the west end of the pipe, the dampener was welded to a flange that was bolted to the discharge end of the pump, keeping it from rotating. When the mechanic removed the bolts from this flange, the dampener rotated and struck Employee #1. He was hospitalized at Kern Medical Center for a compound left ankle fracture, a left elbow laceration, a fractured left clavicle, and torn cartilage in his sternum.

Keywords: FRACTURE, COLLARBONE, LINE CONNECTOR, LACERATION, PIPE, STRUCK BY, ELBOW, PUMP, ANKLE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 314824111 Hospitalized injury Fracture Sales occupations, other business services
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close