Powered by GoogleTranslate

Inspection Detail

Inspection: 314696378 - North American Midway Entertainment

Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation

 

Inspection Nr: 314696378
Report ID: 0454510
Date Opened: 10/11/2010

Site Address:
North American Midway Entertainment
1200 Rosewood Drive
Columbia, SC 29201

Mailing Address:
P O Box 2968, Ridgeland, MS 39158

Union Status: NonUnion

SIC:7999

NAICS: 713990/All Other Amusement and Recreation Industries


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/28/2011

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 05/25/2011


Related Activity
Type Activity Nr Safety Health
Accident 100379536
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 1 5
Current Violations 4 1 5
Initial Penalty $17,975 $0 $0 $0 $0 $17,975
Current Penalty $8,988 $0 $0 $0 $0 $8,988
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100333 A 02/24/2011 03/29/2011 $2,500 $5,000 $0 I - Informal Settlement  
2. 01002 Serious 19100335 A01 I 02/24/2011 03/29/2011 $1,488 $2,975 $0 I - Informal Settlement  
3. 01003 Serious 19100332 B02 02/24/2011 03/29/2011 $2,500 $5,000 $0 I - Informal Settlement  
4. 01004 Serious 19100333 C02 02/24/2011 03/14/2011 $2,500 $5,000 $0 I - Informal Settlement  
5. 02001 Other 19100335 B 02/24/2011 03/02/2011 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 200375251
Event: 10/11/2010
Electric Shock - Direct Contact with Energized Parts

An electrician was inspecting the electrical wiring within the rotating tower section of an amusement ride. The electrician had not deenergized the electric equipment before accessing the wiring. As he was working, he contacted energized circuit parts and was electrocuted.

Keywords: AMUSE PARK/CARNIVAL, E GI IV, ELECTRICAL, ELECTRICIAN, ELECTROCUTED, ELECTRICAL WORK, LOCKOUT, ELEC CIRC PART--MISC, AMUSEMENT RIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 314696378 Fatality Electric Shock Supervisors; electricians & power transm. install.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close