Inspection Detail
Inspection: 314571159 - Moore Brothers
Inspection Information - Office: Sacramento District Office
Site Address:
Moore Brothers
Open Field 1.6 Miles From End Of Wescott Rd
Colusa, CA 95932
Mailing Address:
P.O. Box 124, Grimes, CA 95950
Union Status: NonUnion
SIC:0112
NAICS: 111160/Rice Farming
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/02/2011
Emphasis:
Case Closed: 12/05/2011
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361685746 |
Investigation Summary
On July 16, 2011, Employee #1 was standing in front of an electrical water pump control panel, and it exploded in a rice paddy. Employee #1 was killed and the cause of death was electrocution and mass trauma via shrapnel. At the time this report was written, the case was still being actively investigated by the Colusa County Sheriff Department and apparently also Cal/OSHA.
Keywords: AGRICULTURE, ELECTROCUTED, EXPLOSION, ELECTRIC SHOCK, STRUCK BY, ELECTRICAL BOX, FLYING OBJECT, PUMP
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 314571159 | Fatality | Electric Shock | Supervisors, farm workers |