Powered by GoogleTranslate

Inspection Detail

Inspection: 314492372 - International Ship Repair & Marine Services, Inc.

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 314492372
Report ID: 0420600
Date Opened: 05/10/2010

Site Address:
International Ship Repair & Marine Services, Inc.
1616 Penny Street - Dry Dock #6
Tampa, FL 33605

Mailing Address:
1616 Penny Street, Tampa, FL 33605

Union Status: NonUnion

SIC:3731

NAICS: 336611/Ship Building and Repairing


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/03/2010

Emphasis: S:Shipyards

Case Closed: 07/08/2011


Related Activity
Type Activity Nr Safety Health
Accident 102639150
Referral 203007737 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 1 1
Initial Penalty $11,200 $0 $0 $800 $0 $12,000
Current Penalty $5,600 $0 $0 $0 $0 $5,600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19150157 C 11/04/2010 11/10/2010 $5,600 $5,600 $0 11/29/2010 J - ALJ Decision Citation has been deleted.
2. 01002 Serious 19150181 B 11/04/2010 11/10/2010 $5,600 $5,600 $0 11/29/2010 J - ALJ Decision  
3. 02001 Other 19040029 B03 11/04/2010 11/16/2010 $800 $800 $0 11/29/2010 J - ALJ Decision Citation has been deleted.

Investigation Summary

Investigation Nr: 202528204
Event: 05/10/2010
Electric Shock - Direct Contact with Energized Parts

A drydock electrician was working in a section of the wingwall of a floating dry dock in a shipyard. The employee was checking the electrical connection in a switch box. When the electrician did not return, a second employee called him on the radio, but did not get a response. A third employee checked on the electrician and found him lying on the floor. The electrician was pronounced dead at the scene. The medical examiner's report listed the cause of death as undetermined. However, the report indicated that the employee had a burn on his right hand and a laceration and burn on his left palm. A microscopic examination revealed that the knuckle of the employee's right hand and the left palm had areas of streaming epidermal nuclei. Pathological findings in electrocutions include streaming of the epidermal nuclei. Consequently, OSHA treated the accident as an electrocution.

Keywords: ELEC PROTECT EQUIP, E M, ELECTRICAL, ELECTRICIAN, ELECTROCUTED, ELECTRICAL WORK, LOCKOUT, ELEC CIRC PART--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 314492372 Fatality Electric Shock Electricians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close