Inspection Detail
Inspection: 314441346 - Distribution Construction Co.
Inspection Information - Office: Nc Department Of Labor - Charlotte
Site Address:
Distribution Construction Co.
Intersection Of Shearers Rd & Timberview Ln
Mooresville, NC 28115
Mailing Address:
2609 Greengate Dr., Greensboro, NC 27416
Union Status: NonUnion
SIC:1623
NAICS: 237120/Oil and Gas Pipeline and Related Structures Construction
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 04/20/2010
Planning Guide: Health-Construction
Emphasis: L:Commcon, S:Construction Sep
Case Closed: 07/29/2010
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102099280 |
Investigation Summary
On 15 April 2010, an employee was operating a soil auger inside a shallow trench. The auger was boring a hole underneath the intersection so that an 8 inch natural gas line could be laid. The auger was approximately third of the way across the intersection when the auger struck a 7,200 volt power line, electrocuting the employee operating the auger.
Keywords: ELECTROCUTED, CONSTRUCTION, AUGER, ELECTRIC SHOCK, BORING MACHINE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 314441346 | Fatality | Electric Shock | Construction laborers |