Powered by GoogleTranslate

Inspection Detail

Inspection: 314327792 - Aerotek, Inc.

Inspection Information - Office: High Hazard Unit - Central

 

Inspection Nr: 314327792
Report ID: 0950663
Date Opened: 07/12/2011

Site Address:
Aerotek, Inc.
2101 Franklin Canyon Rd
Rodeo, CA 94572

Mailing Address:
2490 Mariner Square Loop, Ste. 100, Alameda, CA 94501

Union Status: NonUnion

SIC:7363

NAICS: 561320/Temporary Help Services


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/31/2011

Emphasis:

Case Closed: 04/01/2014


Related Activity
Type Activity Nr Safety Health
Accident 102691094
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $0 $0 $0 $2,300 $0 $2,300
Current Penalty $0 $0 $0 $2,300 $0 $2,300
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A07 09/01/2011 09/20/2011 $800 $800 $0 -  
2. 01002 Other 3314 J02 09/01/2011 09/20/2011 $1,000 $1,000 $0 -  
3. 01003 Other 3314 J04 09/01/2011 09/20/2011 $500 $500 $0 -  

Investigation Summary

Investigation Nr: 202508453
Event: 07/11/2011
Employee's Thumb Is Caught in Roller, Partially Amputated

At approximately 9:45 a.m. on July 11, 2011, Employee #1, a Lab Technician of Aerotek, Incorporated, was working alone in the "physical lab" processing the calcine for laboratory sampling. Employee #1 was operating the Morse Brothers Machinery Company, Roll Crusher Model GM-6219, with an Identifier Number of RR69-48. Employee #1 was attempting to clean the "excess, bigger lumps" from the machine that were stuck and thought that the machine was off. The machine is equipped with a hinged interlock guard that does not stop the rollers immediately. The machine has a 6 to 7 second time lapse when the interlock is released. Employee #1 reached in and his right thumb was amputated to the first knuckle. Employee #1 was transported to John Muir Medical Center, Walnut Creek, CA, where he had surgery to reattach his right thumb.

Keywords: AMPUTATED, FINGER, GUARD, THUMB, LOCKOUT, MECH MALFUNCTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 314327792 Hospitalized injury Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.