Inspection: 314326067 - Diamond Refractory Service

Inspection Information - Office: High Hazard Unit - Central

 

Inspection Nr: 314326067
Report ID: 0950663
Date Opened: 01/28/2011

Site Address:
Diamond Refractory Service
3400 East Second St
Benicia, CA 94510

Mailing Address:
8412 Mosley Rd, Houston, TX 77075

Union Status: Union

SIC:1629

NAICS: 237120/Oil and Gas Pipeline and Related Structures Construction


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/20/2011

Emphasis:

Case Closed: 11/21/2012


Related Activity
Type Activity Nr Safety Health
Accident 102690229
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 3 5
Current Violations 5 5
Initial Penalty $27,560 $0 $0 $2,110 $0 $29,670
Current Penalty $0 $0 $0 $22,300 $0 $22,300
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5157 D04 H 07/01/2011 08/17/2011 $7,000 $810 $0 07/25/2011 F - Formal Settlement  
2. 01002 Other 5157 H04 B 07/01/2011 08/17/2011 $650 $650 $0 07/25/2011 W - Empr Withdrew  
3. 01003 Other 5157 H05 C 07/01/2011 08/17/2011 $650 $650 $0 07/25/2011 W - Empr Withdrew  
4. 02001 Other 3210 B 07/01/2011 07/15/2011 $7,000 $20,250 $0 07/25/2011 F - Formal Settlement  
5. 03001 Other 5157 D03 E 07/01/2011 07/15/2011 $7,000 $7,310 $0 07/25/2011 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202508362
Event: 01/28/2011
Employee Fractures Leg and Arm in Fall at Oil Refinery

At about 3:30 a.m. on January 28th, 2011, an employee was working with two coworkers inside the carbon monoxide flue duct removing refractory. This accident site was an oil refinery that processes crude oil into saleable petroleum products. The turnaround work involved in the accident consisted of refractory removal inside a flue duct that was associated with the FCCU. The work crew was moved to a new confined space area in the Duct works because the refractory needed to be immediately removed at the location. The employer required the workers removing refractory to work within four feet of the leading edge associated with the 28 foot vertical fall hazard. Because of the heavy weight of the rivet buster, the work crew traded off using the tool until one got tired. The employee had finished using the rivet buster, and he handed the tool to a coworker. For an unknown reason, he walked the wrong direction into vertical flue duct section. The employee fell 28 feet onto a staging area. The employee's supervisor did not work in the permit confined with the workers. The employee and three coworkers were in a confined space adjacent to the fall hazard. All the employees, including the supervisor, required for all the permitted flue duct spaces to be "100 percent tie off". Nobody was tied-off, because no anchor points were established in the duct. The following factors contributed to the accident: 1) lack of barrier restricting the movement by the fall hazard at the duct, and 2) lack of fall protection for workers inside the duct as required by the confined space permit. The employee sustained a broken femur and compound fracture of his left arm.

Keywords: FRACTURE, CONFINED SPACE, FALL, FALL PROTECTION, ARM, REFINERY, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 314326067 Hospitalized injury Fracture Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.