Powered by GoogleTranslate

Inspection Detail

Inspection: 314323643 - Delta Window Cleaning Company, Incorporated

Inspection Information - Office: American Canyon District Office

 

Inspection Nr: 314323643
Report ID: 0950622
Date Opened: 06/05/2010

Site Address:
Delta Window Cleaning Company, Incorporated
25 Orinda Way
Orinda, CA 94563

Mailing Address:
2062 Walsh Avenue, Ste A, Santa Clara, CA 95050

Union Status: NonUnion

SIC:7349

NAICS: 561790/Other Services to Buildings and Dwellings


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/03/2010

Emphasis:

Case Closed: 02/13/2014


Related Activity
Type Activity Nr Safety Health
Accident 102411535
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2 4
Current Violations 1 1
Initial Penalty $16,650 $0 $0 $900 $0 $17,550
Current Penalty $12,600 $0 $0 $0 $0 $12,600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 2947 12/03/2010 01/05/2011 $0 $225 $0 12/16/2010 F - Formal Settlement Citation has been deleted.
2. 01002 Other 3203 A04 12/03/2010 01/05/2011 $0 $675 $0 12/16/2010 F - Formal Settlement Citation has been deleted.
3. 02001 Serious 2946 B02 12/03/2010 12/13/2010 $12,600 $12,600 $0 12/16/2010 F - Formal Settlement  
4. 03001 Serious 3648 O 12/03/2010 12/13/2010 $0 $4,050 $0 12/16/2010 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 202507711
Event: 06/05/2010
Employees suffer burns from arc flash

At approximately 9:30 am on June 5, 2010, Employee #1 (foreman), and Employee #2, both window cleaners, of Delta Window Cleaning Company, they were tasked to power wash the windows and walls on the outside of the building. They were inside the basket of a Terex TB 85 Aerial Boom Lift. The basket came within a 1 ft. of a 115,000 volt overhead power transmission line. While power washing the windows and walls of the building, the highest point of the man lift came within 1 ft. of the lowest overhead high voltage line, causing an arc flash and creating a fire inside the lift basket. Employee #1 and Employee #2 were engulfed in the flames caused by the arc flash and subsequent fire. Employee #1 suffered burns to 70% of his total body surface area and died of his injuries at 2:30 a.m. on June 23, 2010. Employee #2 suffered burns to 50% of his total body surface area.

Keywords: BURN, ELECTRIC ARC, OVERHEAD POWER LINE, BOOM, FIRE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 314323643 Fatality Electric Shock Janitors and cleaners
2 314323643 Hospitalized injury Electric Shock Janitors and cleaners
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close