Powered by GoogleTranslate

Inspection Detail

Inspection: 314179524 - Nabors Drilling Usa Lp Rig #Fo3

Inspection Information - Office: Dallas Area Office

 

Inspection Nr: 314179524
Report ID: 0626300
Date Opened: 10/26/2010

Site Address:
Nabors Drilling Usa Lp Rig #Fo3
Cr 382
Henderson, TX 75652

Mailing Address:
515 West Greens Rd, Suite 1000, Houston, TX 77067

Union Status: NonUnion

SIC:1381

NAICS: 213111/Drilling Oil and Gas Wells


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/26/2010

Planning Guide: Safety-Manufacturing

Emphasis: L:Oilgas, S:Electrical

Case Closed: 09/29/2011


Related Activity
Type Activity Nr Safety Health
Accident 100785112
Inspection 314179565
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 1 1
Initial Penalty $26,000 $0 $0 $0 $0 $26,000
Current Penalty $5,000 $0 $0 $0 $0 $5,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100304 G05 04/22/2011 04/27/2011 $0 $7,000 $0 05/10/2011 F - Formal Settlement Citation has been deleted.
2. 01002 Serious 19100305 A02 X 04/22/2011 04/27/2011 $7,000 $7,000 $0 05/10/2011 F - Formal Settlement Citation has been deleted.
3. 01003 Serious 19100305 B01 II 04/22/2011 04/27/2011 $5,000 $5,000 $0 05/10/2011 F - Formal Settlement  
4. 01004A Serious 19100305 G02 II 04/22/2011 04/27/2011 $0 $7,000 $0 05/10/2011 F - Formal Settlement Citation has been deleted.
5. 01004B Serious 19100305 G02 III 04/22/2011 04/27/2011 $0 $0 $0 05/10/2011 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 200785111
Event: 10/26/2010
Electric Shock - Direct Contact with Energized Parts

On October 26, 2010, an employee was working for an oil and gas well drilling firm. He was found unresponsive near a water well's electric pump control box. He had been electrocuted. An investigation established certain findings. 1) Circuits, equipment, and enclosures that were part of the water well pump were not grounded. 2) The heavy-duty circuit-breaking plug that was on the power cord to the 3-phase submersible water pump was designed to have and was equipped with a grounding contact. This contact, however, was not used. 3) A 10 AWG, three-conductor (black, yellow, red), type THW cable that used between the breaking plug and the motor contactor did not have a grounding conductor (green). 4) The control panel enclosure that contained the 60-amp motor contactor and the ON/OFF selector switch operator was designed with contacts for securing grounding conductors, but they were not used. 5) The 10 AWG, four-conductor, type THW cable that was used between the motor contactor and submersible pump motor had a grounding conductor, but it was not connected to the grounding contact in the control panel enclosure. The investigation established additional information. The water well had been drilled and the associated equipment installed by an oil field service company that specialized in water well drilling. The aboveground electrical circuits and equipment that controlled the submersible well water pump were repaired twice within a 24-hour period before the fatal incident by representatives of the oil field service company. The power cord had been exposed to physical damage, as pallets of mud-mixing supply were placed on top of the cord. The power cord between the plug and motor contactor had at least three separate splices and showed signs of burning. The electrical cords to the submersible pump entered an industrial control panel enclosure and were not connected to strain relief devices or fittings. A tug on the cord could be directly transmitted to terminal screws.

Keywords: E GI V, ELEC PROTECT EQUIP, ELECTRICAL, INADEQUATE MAINT, ELECTROCUTED, OIL WELL DRILLING, ELEC CIRC PART--MISC, ELECTRIC CONDUCTOR, ELECTRICAL SPLICE, GAS WELL DRILLING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 314179524 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.