Inspection Detail
Inspection: 314145772 - Applied Materials, Inc.
Inspection Information - Office: Fremont District Office
Site Address:
Applied Materials, Inc.
44050 Fremont Blvd.
Fremont, CA 94538
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3674
NAICS: 334413/Semiconductor and Related Device Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/06/2010
Emphasis: L:Arrastim
Case Closed: 04/13/2010
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102677127 |
Investigation Summary
On February 11, 2010, Employee #1, an employee of Applied Materials, was cleaning an acid station. She was spraying a diluted mixture of HF, Nitric acid and DI water that was spilled on top of the sink using a Nitrogen gun. The chemical mixture splashed into Employee #1's eyes and burned them. An eye wash was used to flush the eyes of Employee #1. She was taken by paramedics to Washington Hospital for treatment of her injury and was released the same day.
Keywords: BURN, EYE, CLEANING, CHEMICAL BURN, SPILL, CHEMICAL
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 314145772 | Hospitalized injury | Other | Occupation not reported |