Powered by GoogleTranslate

Inspection Detail

Inspection: 313876864 - North Florida Tower Service, Inc.

Inspection Information - Office: Jacksonville Area Office

 

Inspection Nr: 313876864
Report ID: 0419700
Date Opened: 05/05/2010

Site Address:
North Florida Tower Service, Inc.
State Road 357
Hines, FL 32347

Mailing Address:
1059 Se Press Ruth Road, Lake City, FL 32025

Union Status: NonUnion

SIC:1791

NAICS: 238190/ Other Foundation, Structure, and Building Exterior Contractors


Inspection Type: Accident

Scope: Complete

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 06/21/2010

Emphasis: L:Fall, S:Commercial Constr, S:Fall From Height

Case Closed: 08/30/2010


Related Activity
Type Activity Nr Safety Health
Accident 101357978
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260501 B01 08/05/2010 08/10/2010 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 201354024
Event: 05/04/2010
Employee Is Killed in Fall from Communication Tower

On May 4, 2010, an employee and a coworker were working on a 400-foot communication tower. They were removing a 4-foot tower at the 120-foot level, and removing and replacing a 16-foot antenna that was on the top of the tower. As they climbed the tower, they were also disconnecting the straps that held the antenna wires in place. While at the 240-foot level, the employee repositioned himself from one side of the tower to the other. He wore a harness which had three lanyards attached to it so that he could be secured at all times, but he was using only one of the lanyards to secure himself. While he was repositioning himself, he disconnected his one lanyard, and before he could reconnect it to the next connection or anchor point, he fell. He fell onto the top of a mechanical building and then to the ground. He was pronounced dead at the scene.

Keywords: COMMUNICATION TOWER, LANYARD, FALL, FALL PROTECTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313876864 Fatality Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close