Powered by GoogleTranslate

Inspection Detail

Inspection: 313874042 - Metal-Bilt Construction, Llc

Inspection Information - Office: Jacksonville Area Office

 

Inspection Nr: 313874042
Report ID: 0419700
Date Opened: 01/15/2010

Site Address:
Metal-Bilt Construction, Llc
900 Sw 38th Ave
Ocala, FL 34474

Mailing Address:
7280 Westpointe Blvd, Suite 817, Orlando, FL 32835

Union Status: NonUnion

SIC:1791

NAICS: 238120/Structural Steel and Precast Concrete Contractors


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/18/2010

Emphasis: S:Commercial Constr, S:Struck-By

Case Closed: 02/08/2012


Related Activity
Type Activity Nr Safety Health
Accident 101357853
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $4,900 $0 $0 $1,200 $0 $6,100
Current Penalty $3,120 $0 $0 $0 $0 $3,120
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260758 B 06/22/2010 07/16/2010 $3,120 $4,900 $0 I - Informal Settlement  
2. 02001 Other 19040032 B03 06/22/2010 06/25/2010 $0 $600 $0 I - Informal Settlement  
3. 02002 Other 19040032 B03 06/22/2010 06/25/2010 $0 $600 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 201353984
Event: 01/15/2010
Employee Is Killed When Steel Column Falls

On January 15, 2010, Employee #1 was installing a 0.375-in. wire rope to provide support for two vertical steel columns (I beams), known as G-18 and G-19. Each column was 33 ft 4-in. tall, 18-in. wide, and weighed 1,750 lbs. Columns G-19 and G-18 were separated by 24 ft 7-in. The wire rope was intended to form an "X" cross brace between the two columns; from the top of one column to the bottom of the other column. On January 13, 2010, another crew had drilled four anchor bolt holes for column G-19, filled the holes with epoxy and inserted the bolts. On January 15, 2010, a forklift hoisted the column onto bolts and held it in place until the anchor nuts were secured on the bolts. Then the forklift was removed. While Employee #1 was installing the wire rope, Column G-19 fell and struck him. He was killed. The bolts had pulled out of the epoxy. The coworker who had injected the epoxy into the holes had not been trained in how to ensure the epoxy was properly mixed, properly applied or injected, or how to ensure that the epoxy had properly cured.

Keywords: UNSECURED, WIRE ROPE, COLLAPSE, STEEL COLUMN, STEEL CONNECTOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313874042 Fatality Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.