Inspection Detail
Inspection: 313680126 - Kerr Concentrates Inc
Inspection Information - Office: Or-E-Salem 1054100
Site Address:
Kerr Concentrates Inc
2340 Hyacinth St Ne
Salem, OR 97301
Mailing Address:
975 Oak St Ste 615, Eugene, OR 97401
Union Status: NonUnion
SIC:2037
NAICS: 311411/ Frozen Fruit, Juice, and Vegetable Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/12/2010
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 07/13/2010
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $500 | $0 | $0 | $0 | $0 | $500 |
| Current Penalty | $500 | $0 | $0 | $0 | $0 | $500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100147 C04 I | 03/22/2010 | 04/01/2010 | $500 | $500 | $0 | - |
Investigation Summary
On January 12, 2010, Employee #1, of Kerr Concentrates Inc, was replacing a sensor on a water heating system and failed to release all the hot water. The water temperature was approximately 200 degrees Fahrenheit; gravity caused approximately one-gallon of this hot water to pour out onto his right leg. Employee #1 sustained a first to second degree burn on his right leg and was hospitalized.
Keywords: BURN, REPAIR, HOT WATER TANK, HOT WATER, LEG
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 313680126 | Hospitalized injury | Burn/Scald(Heat) | Machinery maintenance occupations |