Powered by GoogleTranslate

Inspection Detail

Inspection: 313648917 - Miller Environmental Corp

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 313648917
Report ID: 0950635
Date Opened: 07/26/2013

Site Address:
Miller Environmental Corp
280 Pier T Lane
Long Beach, CA 90802

Mailing Address:
1130 W Trenton Ave, Orange, CA 92867

Union Status: Union

SIC:1795

NAICS: 238910/Site Preparation Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/23/2014

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 04/22/2016


Related Activity
Type Activity Nr Safety Health
Accident 362460784
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $18,000 $0 $0 $0 $0 $18,000
Current Penalty $10,800 $0 $0 $0 $0 $10,800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 2946 A 01/23/2014 01/28/2014 $10,800 $18,000 $0 02/07/2014 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202532156
Event: 07/24/2013
Employee Suffers Burns When Lift Contacts Power Line

At approximately 3:40 p.m. on July 24, 2013, Employee #1 was working on the demolition of an off ramp from a bridge. The off ramp was broken down into small pieces, using heavy equipment but several of the small pieces had lodged on the girders and bents that supported the off ramp. Employee #1 and a coworker were placed in the basket of a boom lift with an air hose to blow off the remaining pieces of concrete that had settled on the girders as well as the bents. Employee #1 was operating the boom lift and a coworker was standing a few feet behind and was holding the nozzle of the air hose, which was connected to the compressor on the ground. At one point, the hose got entangled with a piece of steel below, and in an attempt to release the hose, the employee raised the boom lift basket approximately 25-30ft in an upward direction and then rotated the base of the lift clockwise. As the basket approached the energized overhead lines, an arch occurred. Employee #1 suffered third degree burns to the face, neck, shoulder, arm and left plank. Employee #1 was taken to an area hospital, where he was treated and remained hospitalized.

Keywords: BURN, SHOULDER, DEMOLITION, BOOM, RAMP, ELEC UTILITY WORK, TRUCK BOOM, ARM, BRIDGE, FACE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313648917 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.