Inspection: 313641664 - Jacobs Engineering

Inspection Information - Office: Labor Enforcement Task Force (Letf) Unit - Central

 

Inspection Nr: 313641664
Report ID: 0950664
Date Opened: 10/04/2010

Site Address:
Jacobs Engineering
Temblor Thermal Area 1y Gs 15
Mc Kittrick, CA 93251

Mailing Address:
26251 Highway 33, Fellows, CA 93224

Union Status: NonUnion

SIC:1389

NAICS: 213112/Support Activities for Oil and Gas Operations


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/17/2010

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 12/17/2010


Related Activity
Type Activity Nr Safety Health
Accident 362460362

Investigation Summary

Investigation Nr: 202530317
Event: 09/27/2010
Plumber Is Burned by Steam from Failed Fitting

On September 27, 2010, Employee #1, an oil well field contract employee, was returning Chevron's 8 in. steam header back into service after planned maintenance to replace three 3 in. steam valves on three branch lines. After the valves were replaced, the steam header was returned to service. Employees #1 and three coworkers were walking along the steam header catwalk checking the valve positions. A 2 in. 90 degree elbow, unrelated to the maintenance being conducted, suddenly failed. Steam pressurized to approximately 1,000 psi and 500 to 650 degrees Fahrenheit discharged onto Employee #1, who was knocked down onto the catwalk. One coworker shut off the steam flow while the other two rescued Employee #1. He was hospitalized for second- and third-degree burns on 80 percent of his body.

Keywords: BURN, STEAM LINE, STEAM, HIGH PRESSURE PIPE, HIGH PRESSURE, VALVE, OIL WELL SERVICING, PIPE, ELBOW, HIGH TEMPERATURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313641664 Hospitalized injury Burn/Scald(Heat) Plumbers, pipefitters and steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.