Powered by GoogleTranslate

Inspection Detail

Inspection: 313512683 - Brithinee Electric

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 313512683
Report ID: 0950633
Date Opened: 05/12/2011

Site Address:
Brithinee Electric
620 S Rancho Ave
Colton, CA 92324

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3677

NAICS: 334416/ Electronic Coil, Transformer, and Other Inductor Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/17/2011

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 06/20/2012


Related Activity
Type Activity Nr Safety Health
Accident 102747425
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $1,100 $0 $1,100
Current Penalty $0 $0 $0 $200 $0 $200
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A02 10/17/2011 10/20/2011 $100 $550 $0 10/28/2011 F - Formal Settlement  
2. 01002 Other 3650 T33 10/17/2011 10/20/2011 $100 $550 $0 10/28/2011 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202634036
Event: 04/28/2011
Employee's Hand Is Injured When Struck by Falling Stator

At approximately 8:30 a.m. on April 28, 2011, Employee #1, a regular employee who had been employed as a mechanic for eleven years, was working at a manufacturing facility, where electrical motors were manufactured, rewound, and repaired. Employee #1 was tearing down a motor assembly at Work Station Number 1, in the Tear Down & Assembly Department. Employee #1 inadvertently suspended the motor assembly by attaching the rotor shaft end to a hook of a KONECRANES 20-ton-capacity bridge crane and positioned it over the work table. He used an electrical impact gun to remove three of four bolts from the end bell, which kept the rotor bearing plate attached to the stator casing. As he unscrewed the fourth bolt, the stator, which weighed 780 pounds, became free, fell down on the work table, and pinned Employee #1's left hand between it and the table. Employee #1's sustained crushing injuries to his left hand, which apparently consisted of bruises and/or abrasions. Employee #1 was taken to the Loma Linda University Medical Center in Loma Linda, CA for treatment. Surgery was performed, and Employee #1 was hospitalized for more than 24 hours. The employer reported the serious injury accident to the Division at 3:20 p.m. on April 28, 2011.

Keywords: PINNED, MECHANIC, SUSPENDED LOAD, CRUSHED, ABRASION, STRUCK BY, FALLING OBJECT, HAND, CONTUSION, INATTENTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313512683 Hospitalized injury Bruise/Contus/Abras Specified mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close