Powered by GoogleTranslate

Inspection Detail

Inspection: 313480105 - Headway Technologies Inc.

Inspection Information - Office: Fremont District Office

 

Inspection Nr: 313480105
Report ID: 0950612
Date Opened: 08/28/2009

Site Address:
Headway Technologies Inc.
497 South Hillview Dr
Milpitas, CA 95035

Mailing Address:
678 South Hillview Dr, Milpitas, CA 95035

Union Status: NonUnion

SIC:3674

NAICS: 334413/Semiconductor and Related Device Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/20/2009

Emphasis: L:Arrastim

Case Closed: 11/19/2009


Related Activity
Type Activity Nr Safety Health
Accident 102639861
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $3,375 $0 $0 $0 $0 $3,375
Current Penalty $3,375 $0 $0 $0 $0 $3,375
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5194 F04 10/29/2009 11/03/2009 $3,375 $3,375 $0 -  

Investigation Summary

Investigation Nr: 202586426
Event: 07/03/2009
Employee Is Exposed to Chemicals Spread on Floor

On July 3, 2009, Employee #1 poured the wrong chemical into a pressure vessel, located in service chase, and brought the canister back to the chemical laboratory to dispose the mixture. The mixed chemicals were transferred by another technician to a carboy container and set it on the floor and left. A chemical exothermic reaction began within the carboy. The reaction caused a rapture of the container and release of 4-gallons diluted ammonium hydroxide, hydrogen peroxide, and deionized water. The chemical spill spread on the floor. When Employee #1 entered the chemical lab, he slipped on the floor. Employee #1 was rinsed with water and was taken by ambulance to the hospital, where he was hospitalized.

Keywords: AMMONIA, PRESSURE VESSEL, FLOOR HOLE, HYDROGEN PEROXIDE, SLIP, CHEMICAL BURN, FALL, SPILL, CHEMICAL, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313480105 Hospitalized injury Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close